AIR CPU1001
14
TechnIcal sPecIfIcaTIon
Table 2:
Technical specification
compressor
Max pressure
8bar (Factory setting 6bar)
Noise in app.
50dB
The compressor is oil free and drains automatically.
The compressor automatically switches off if fault or vandalism causes
the compressor to run continuously for the specified Switch off time.
Switch off time
5min
electrical data
Voltage
230Vac
Frequency
50/60Hz
Power
690W
Current
3A
Consumption
180kWh (Estimated annual electricity consumption)
Protection degree
IP45 IEC 60529
Temperature range
-10 - +45°C
Altitude
up to 2000 m
Relative humidity
80%
Class
Class 1
WEEE
2002/96/EC
CE
EN/IEC 61010-1
MaInTenance
Regular maintenance will prolong the life of your VEKSØ product and also
ensure optimal operating performance.
VEKSØ recommends that AIR CPU1001 should be maintained according to
the enclosed Operation & Maintenance manual from the compressor
manufacturer and the following maintenance schedule.