AIR CPU1001
15
Table 3:
Maintenance list
Maintenance list
Monthly
semi
annual
annual
Check the pump handle and rubber gaskets
for proper functioning. Replace gaskets if
necessary.
•
The switch off time of the compressor is 5
minutes. Activate the pump handle valve
for 5 minutes, and ensure the compressor
stops.
•
When the HPFI switch located in the fuse
box (Figure 1, item 2) is switched on (1)
it must trip when the test button (Test) is
pressed.
•
Remove dirt from the cabinet with deter-
gent. For regularly cleaning, detergent
should not contain abrasives or solvents.
•
Check pressure on internal pressure gauge
after compressor is activated and pressure
regained. Maximum is 8bar and factory
setting is 6bar.
•
Graffiti
Graffiti can be removed with benzene, turpentine or in difficult cases
with metyletylketon (MEK)*.
Cleaning must be followed by a wax treatment.
*By using metyletylketon (MEK) the surface may not be rubbed more
than maximum 4-5 times during each application.
Repairing minor damage:
1. Gently sand damaged area, without damaging coating further.
2. Remove loose particles.
3. Apply refinish.
Recommended products:
refinish:
Standard paint in matching RAL color.
cleaner:
Neutral pH detergent; value from 5 to 8
Wax:
General-purpose wax used to protect painted metal surfaces
MaInTenance