Appendix C — Filter Manager Error/Status Codes
141
Filter Manager Error/Status Codes
-713
Error opening the Real or codec Registry.
Use RegEdit and/or RegCtr-
lPnl to check the existence
and state of the Real and
codec tables.
(See Appendix B.)
-714
Error opening the Real or codec Registry.
Use RegEdit and/or
RegCtrlPnl to check the
existence and state of the
Real and codec tables
(Appendix B).
-715
Error creating main Real processing thread.
Error creating main Real
processing thread.
-717
Conversion of an input string from Unicode
failed.
Use RegCtrlPnl to check the
input parameters for Real.
-718
Failed to create the in-pin from the CVPro to the
Real component.
Ascertain that both Cin-
ProSerCom and RealEncode
are registered, as well as
CVProServer. Make certain
that previous encode closed
down cleanly.
-719
Failed to initialize in pin listed above.
-720
Real failed to compress video frame.
May have received bad data
from CVPro. Check content
of tape and quality of
MPEG-2 file, if possible.
-721
Real failed to compress audio frame.
May have received bad data
from CVPro. Check content
of tape and quality of
MPEG-2 file, if possible.
-723
Real engine failed during encode.
Use RegCtrlPnl to check the
input parameters for Real.
-724
Real engine failed during setup.
Use RegCtrlPnl to check the
input parameters for Real.
Filter Manager Error/Status Codes (Continued)
Error Code
Meaning
Comments
Table C-1. Filter Manager Error/Status Codes (Continued)