background image

that,  as  the  occasion  arises,  the  preliminary  filter  scale  and  impeller  should  be     
cleaned before putting the pump into use again (see also below). 

Thermal security device

To prevent overheating and consequently damage to the motor, Green Line Pumps 
have  a  built-in  thermal  security  device.  Remember,  if  the  motor  is  deactivated  by 
overheating you should check the following points before starting the pump again. 
Stop any activities on the pump.
Always switch off the power voltage by pulling the plug out of the receptacle.

l

Is the pump sufficiently immersed in the water?

l

Is the preliminary filter scale polluted, as a result of which the water supply to the 
pump stagnates?

l

Is the impeller or hose socket polluted?

l

Has the pump cooled down sufficiently before restarting it?

As soon as these points have been found to be in order, the pump can be restarted.

Impeller (see illustration)

Not  only  to  remove  trouble,  but  also  to  be  sure  of  a  satisfactory  water  yield,  the 
impeller should be cleaned regularly. To this end you should proceed as follows:

l

Deactivate the power voltage and remove the pump from the pond.

l

Open the preliminary filter scale by opening the green clamps.

l

Remove the large and small bracket by removing the screws.

l

Loosen the swivel of the pump outlet and remove the pump from the filter scale.

l

Open the motor case by removing the 4 screws.

l

Carefully remove the impeller from the motor case.

l

Clean all parts under freely running water, using a soft brush.

l

Assemble all parts in reverse order. Take care that the impeller will run smoothly 
again in the motor housing and that the rubber rings are mounted in the right way. 

USE IN WINTER

If the outside temperature does not go down below -5°C for a longer period of time 
and the pump is sufficiently immersed in water, a Green Line pond pump can also be 
normally used in winter. In severe winters with temperatures lower than -5°C it is to be 
recommended to remove the pump from the pond. Properly clean both the pump 
and the pre-liminary filter scale. Inspect the pump and the flex for any damage. To 
prevent the rubbers from drying out, it is to be recommended to store the pump wet, 
for example in a bucket of water.

CAPACITY

The required pump capacity depends on the type of pond and the filter system.

Model

 

a lot of koi, no plants 

a lot of fish, few plants 

few fish, a lot of plants

   5000 

   2500 litres 

   5000 litres 

10.000 litres

   8000 

   4000 litres 

   8000 litres 

16.000 litres

12500 

   6000 litres 

12.500 litres 

25.000 litres

15000 

   7500 litres 

15.000 litres 

30.000 litres

20000 

10.000 litres 

20.000 litres 

40.000 litres

Summary of Contents for Green Line 12500

Page 1: ...GEBRUIKSAANWIJZING GREEN LINE POND PUMP GEBRAUCHSANWEISUNG GREEN LINE POND PUMP MODE D EMPLOI GREEN LINE POND PUMP USER INSTRUCTIONS GREEN LINE POND PUMP brings life to your pond...

Page 2: ...ller for Green Line Pond Pumps for Green Line 5000 8000 for Green Line 12500 15000 20000 for Green Line for Green Line 5000 for Green Line 8000 for Green Line 12500 for Green Line 15000 for Green Line...

Page 3: ...en mag bij beschadiging niet wordenvervangen Mochtereenbeschadigingoptredenaandekabel danmagde pompnietwordengebruikt Bij werkzaamheden in of om het water moet van alle ondergedompelde of met de vijv...

Page 4: ...haal en de rotor worden schoongemaakt alvorens de vijverpomp weer in gebruik te nemen Thermische beveiliging Om oververhitting en daarmee schade aan de motor te voorkomen hebben de Green Line vijverpo...

Page 5: ...st 5000 40 W 220 240 V 50 60 Hz Max 3 5 m 5000 l h 8000 70 W 220 240 V 50 60 Hz Max 4 5 m 8000 l h 12500 110 W 220 240 V 50 60 Hz Max 5 5 m 12000 l h 15000 135 W 220 240 V 50 60 Hz Max 6 0 m 14500 l h...

Page 6: ...nsatz dieser Pumpen in Schwimmb dern ist nicht erlaubt Das Pumpengeh use muss mindestens 10 cm und darf maximal 2 m unter dem Wasserniveau platziert werden Gebrauchen Sie die Pumpe im Teich nie ohne V...

Page 7: ...odurch die Wasserzufuhr stagniert l Ist der Rotor oder Schlaucht lle verschmutzt l Ist die Pumpe schon ausreichend abgek hlt um wieder zu laufen WenndiesePunktekontrolliertundinOrdnungsindkanndiePumpe...

Page 8: ...Falle der Reparaturen Ver nderungen oder Erweiterungen am Produkt von anderen als Velda Bei Inanspruchnahme von GarantieleistungenistderdatierteKaufbelegimOriginalvorzulegen F rdieGarantie abwicklung...

Page 9: ...mais faire tourner la pompe vide c est dire sans qu elle soit aliment e en eau Le moteur pourrait se d t riorer La temp rature de l eau aspir e ne doit pas tre sup rieure 35 C Si la pompe est enti rem...

Page 10: ...tion de l alimentation de la pompe en eau l La roue aub e ou raccord est elle encrass e l La pompe a t elle suffisamment refroidi avant sa remise en route Une fois ces v rifications effectu es et une...

Page 11: ...30 000 litres 20000 10 000 litres 20 000 litres 40 000 litres GARANTIE Velda garantit le fonctionnement parfait de cet appareil pendant une p riode de 24 mois compter de la date d achat La garantie es...

Page 12: ...e maximum 35 C When the pump is completely installed it can be connected to the power supply INSTRUCTIONS FOR USE Mount the discharge hose socket optional with L connector including sealing rings toth...

Page 13: ...small bracket by removing the screws l Loosen the swivel of the pump outlet and remove the pump from the filter scale l Open the motor case by removing the 4 screws l Carefully remove the impeller fr...

Page 14: ...W 220 240 V 50 60 Hz Max 7 0 m 16000 l h GUARANTEE Velda guarantees the correct functioning of this apparatus for a period of 24 months after purchase The warranty expires in case of repairs changes...

Page 15: ...l Green Line 35 C l Green Line l 10 2 l l l l l 35 C l L Velda Green Line 6...

Page 16: ...Green Line l l l l l l l l l 4 l l l Green Line 5 C 5 5000 2500 5000 10 000 8000 4000 8000 16 000 12500 6000 12 500 25 000 15000 7500 15 000 30 000 20000 10 000 20 000 40 000...

Page 17: ...220 240 50 60 3 5 5000 8000 70 220 240 50 60 4 5 8000 12500 110 220 240 50 60 5 5 12000 15000 135 220 240 50 60 6 0 14500 20000 200 220 240 50 60 7 0 16000 Velda Green Line 24 Velda Veldawww velda com...

Page 18: ......

Page 19: ......

Page 20: ...brings life to your pond Design Research Development Velda The Netherlands www velda com info velda com Green Line pumps online GAW126595060...