www.velgehome.com
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS FOR
COOKER HOOD VCCH 9003.1 B / VCCH 9003.1 W, 230-240 VAC 50 H
Exhausting cooker hood. The equipment is constructed in accordance with European Standards and with the requirements included in the
following Directives: 006/95EC (Low Voltage Directive), 2004/108 (Electromagnetic Compatibility).
INSTALLATION
Read the instruction manual before installing and/or using the hood. The
unit must be fitted at a distance of at least 65 cm. from the cooking hob.
If the mounting instructions of the gas cooker indicate a wider distance,
respect it. The unit must not be mounted above cookers fitted with top
radiant plate. Respect all the air discharge regulations.
The air must not be discharged in a pipe used to discharge exhaust fumes
produced by gas-fed equipments or fuel-fed equipments (this does not
apply to filtering hoods).
The room must be adequately ventilated when the hoods is used together
with other gas-fed or fuel-fed equipments.
For an easy access, it is advisable to move possible furniture under the
installation area.
Installation of the hood onto the wall.
The hood is equipped with all the necessary fastenings for its installation,
which are suitable for most surfaces. Verify that the installation surface
is strong.
Installation must be carried out by qualified installers according to
present regulations.
1) Draw and drill the wall as in
Picture 2
2) Fix on the wall the screw anchors with its support
(A).
3) Fix with screw anchors
(C)
the support of the telescopic chimney
(B).
4) Put the screw anchors on the holes
(D)
5) Fix the hood to the screw anchors see point 2), two people are needed
for this operation.
6) Block the equipment with screws
(E),
to reach these fastenings open
the frontal panel.
7) Apply the pipe and/or the drain connection.
8) Fix the telescopic chimney on the vents on the upper part of the hood
and fix it to the support with screws
(F).
ELECTRICAL CONNECTIONS
This equipment must be connected to a grounding plant.
Two types of electrical connection can be used:
1) Using a standard plug to be connected to the power cable and inserted
in a mains socket which must be accessible (so that the plug can be
disconnected when servicing is carried out). Make sure that the plug is
accessible also after the complete installation of the equipment.
2) By means of a fixed mains connection, fitting a bipolar switch, which
GB
PRESENTATION
The unit
(Picture 1)
is composed of the following elements:
1) hood module
2) telescopic chimney (optional)
3) drain connection (optional)
4) exhaust pipe (optional)
Summary of Contents for Fannaraki
Page 1: ......
Page 26: ...www velgehome com ...
Page 27: ...www velgehome com 150 140 110 250 Min 1090 Max 1300 600 900 1200 306 350 170 230 150 735 86 ...