PP-42A
24
40: R/C-MONITOR
Current value of RC signal
41: RC-TRIM.OFF
RC signal value for STOP. Push the SET push-button (the > and < starts flashing). Set the
RC transmitter signal for STOP and confirm it by the SET push-button (the > and < stops
flashing and it is entered in the engine memory). 0.90 ms by default
42: RC-IDLE
RC signal value for IDLE. Push the SET push-button (the > and < starts flashing). Set the
RC transmitter signal for IDLE and confirm it by the SET push-button (the > and < stops
flashing and it is entered in the engine memory). 1.00 ms by default
43: R/C-100 %
RC signal value for ENGINE N100 %. Push the SET push-button (the > and < starts
flashing). Set the RC transmitter signal for 100 % and confirm it by the SET push-button
(the > and < stops flashing and it is entered in the engine memory). 2.00 ms by default
44: FAILS-TIME
Time that starts running upon RC signal loss and after which lapse the engine is switched
off. Upon RC signal loss, the speed is set to 45:FAILS-THROTTL. Setting range from 0 to
60 s in 1 s steps. 5 s by default
45: FAILS-THROTTL
Engine speed that will be set upon RC signal loss. Setting range from IDLE to ENGINE
N100 % in 100 rpm steps
0 %
- engine stop
1
– 100 %
- engine speed IDLE to 100 %
0 % by default
46: THROTTLE-TYPE
Linear function for setting engine speed or thrust according to the throttle lever
SPEED
- the throttle lever works linearly with engine speed
THRUST
- the throttle lever works linearly with engine thrust
THRUST by default
47: CONTROL-TYPE
Selection of engine control
RC
- engine starting, control and switch off by RC input
UART
- engine starting, control and switch off by serial line
RC by default