background image

DCM97K v2                                                                                                                                               GB 

 

PART 1 : THE DIGITAL MULTIMETER (DMM) 

 
1. SAFETY INFORMATION 
 
This multimeter has been designed in accordance with UL1244 and IEC-1010 
concerning safety requirements for electronic measuring instruments with an 
overvoltage category (CAT II) and pollution 2. 
Follow all safety and operating instructions to ensure that the meter is used safely 
and is kept in good working order. 
 
1.1. Preliminary 
 
The user should observe all standard safety rules : 
 

l

 Do not abuse the device. 

l

 Full compliance with safety standards can be guaranteed only if the device is 

used with the supplied test leads. If necessary, they should be replaced with 
identical leads or leads with identical electronic ratings. All measuring leads 
should be in good condition. 

 
1.2. Use 
 

l

 Observe a warm-up delay of at least 60 seconds. 

l

 The display may become unstable and the readings inaccurate if the multimeter 

is used in the vicinity of noise-generating equipment. 

l

 Never exceed the limit values of the various measurement ranges as indicated 

in this manual. 

l

 Disconnect all test leads from circuits that are currently being tested before 

selecting a different function. 

l

 Never perform resistance measurements on live circuits. 

Always be careful when working with voltages in excess of 60VDC or 30Vrms 
AC. 

Keep your fingers behind the probe barriers while using the device. 

 
1.3. Symbols 
 

 

 Important safety information, consult the manual. 

 

 Earth ground 

 

 Double insulation (Protection Class II) 

Summary of Contents for DCM97K

Page 1: ...ion 2 Separable Meter Digital Multimeter AC Current Transducer Afneembare Meter Digitale Multimeter AC Stroomtang M tre s parable multim tre num rique pince amp rem trique CA User Manual Gebruikershan...

Page 2: ...l multimeter DMM and an AC current transducer The DMM can be used individually for DC AC voltage measurements and for measuring resistance diodes and continuity The meter can be used to measure AC cur...

Page 3: ...with identical leads or leads with identical electronic ratings All measuring leads should be in good condition 1 2 Use l Observe a warm up delay of at least 60 seconds l The display may become unstab...

Page 4: ...the explanation for the various numbered controls in order to familiarise yourself with the functions and keys of the front panel Digital Display All measured values are displayed on an LCD with 3200...

Page 5: ...x 5 seconds Press the key again to reactivate the back light 3 SPECIFICATIONS Max accuracy is achieved during a one year period after calibration at a temperature of 18 to 28 C 64 F to 82 F and a max...

Page 6: ...Range Resolution Accuracy 3V 1mV 30V 10mV 300V 100mV 600V 1V 0 8 of rdg 3 digits Input Impedance 10M Frequency Response 40Hz 400Hz 40Hz 200Hz for the 3V range Overload Protection 600VDC or 600Vrms AC...

Page 7: ...V input terminal and the black test lead to the COM terminal 2 Place the function switch in the position 3 Push the blue FUN key until the VAC or VDC function is reached 4 Connect the test probe and...

Page 8: ...30M range This is normal when high resistances are being measured 2 The overrange indication OL will be displayed if the input is not connected e g with an open circuit 4 3 Continuity Test buzzer 1 C...

Page 9: ...eed to be replaced when the sign appears on the LCD Remove the screws of the battery cover and open the cover Replace the old batteries with two new 1 5V batteries supplied Note Please observe all app...

Page 10: ...king order by following the instructions in this manual 1 1 Symbols 2 DESCRIPTION 2 1 Front View Consult fig 3 and follow the procedure outlined below to familiarise yourself with the AC current trans...

Page 11: ...f 80 Accuracy specifications are rendered as follows of reading digits 3 1 General Current Range 0 1A to 300A AC rms Output Voltage 1mVAC per 0 1A AC Working Voltage 600V CAT II in accordance with IEC...

Page 12: ...and or flawed if the device is used in the vicinity of noise generating equipment This instrument should not be used on uninsulated conductors at a voltage in excess of 250Vrms AC or 250VDC 5 AC CURR...

Page 13: ...DCM97K v2 GB 12 FIGURE 5...

Reviews: