36
8 0
Door Forced Open
Warning & Time
FUNCTION MODE / TIME:
0---OFF
1-999 Seconds
80
FUNCTION / TIME
#
Mode = 0,
Door Forced
Open
Warning OFF
8 1
Propped-up
Warning & Time
81
FUNCTION / TIME
#
Mode = 0,
Propped-up
Warning OFF
9 0
Egress Delay
Warning & Alarm
CODE 1 - FUNCTION MODE:
1---Momentary, No warning
2---Momentary, with warning
3---Momentary, with w
Alarm
4---Hold Contact, No warning
5---Hold Contact, with warning
6---Hold Contact, with w
Alarm
CODE 2 - DELAY TIME:
0---No Delay
1-99 Seconds
90
CODE 1
CODE 2
#
Mode = 1
Momentary,
No warning
TIME = 0
No Delay
9 1
Door Opening
Alarm & TIMER
ALARM TIME:
0---No Alarm
1-999 Seconds
91
ALARM TIME
#
Time = 0,
No Alarm
9 4
Operation Mode &
Wiegand Output
MODES OF WIEGAND OUTPUT
0---Stand Alone Keypad-Valid
Codes & Cards Only
1---Reader-All Codes & Cards
2---Master Keypad-Valid Codes &
Cards only
3---Slave Keypad-Valid Codes &
Cards only
94
WIEGAND O/P MODE
#
Mode =
0 Keypad
Mode
SYSTEM
CODES
FUNCTION
CODE ENTRY
RESULTS
0 0 0 0
Factory Set Master Code
for User to set system in
programming Mode at the
first time.
THIS IS NOT A
PERMANENT SYSTEM
CODE & IT IS CHANGED
IF A NEW MASTER CODE
IS PROGRAMMED.
0000 * *
OR
NEW MASTER CODE
* *
System in Programming Mode
9 9 9 9
REFRESH CODE -- Refresh
the system and set all its
function back to default
values.
9999 #
All programmed data are cleared
and back to the default values
except the Master Code
8 0 8 0
DAP CODE-- Direct access
to programming mode.
Valid only in the power-up
delay period
8080 #
System in Programming Mode
0 9 9 9
USER PINs / Codes / Cards
whole group clearance
Code - Key in the Code
to clear all the users in the
Location
LOCATIONS:
10--- User Group 1
20--- User Group 2
30--- User Group 3
40--- Vistor Group
41--- Duress Group 1
42--- Duress Group 2
43--- Duress Group 3
LOCATION NO.
0999 #
W h o l e g r o u p o f u s e r s i n t h e
selected location are cleared
* *
Exit Programming Code
**
The system back to normal opration
after programming