The Duress Output will switch to (
−) ground when duress code is entered. You may use it to
turn ON an LED lamp and / or a small buzzer to notify a guard; or connect it to a 24 hour
Normally Open protection zone of an alarm system.
Only one connection option is recommended. Make sure that the sink current does not
exceed the maximum rating of 100mA.
Use the Normally Open (N.O.) output contact to shunt a Normally Closed (N.C.) protection zone
of an alarm system.
Set output contact to Start / Stop Mode (Programming Option 51).
Use the (N.O.) or (N.C.) output contact to make arm-disarm control of an alarm system.
Consult your alarm control panel manual for the appropriate output contact to be used in
arm-disarm control.
Usually set output 2 to Momentary mode (Programming Option 501) for multi station systems and
Start / Stop mode (Programming Option 51) for single station ststems.
(D) DURESS OUTPUT
(E) OUTPUT 2
33