background image

Remote control by telephone

 

K6501

 

ILLUSTRATED ASSEMBLY MANUAL 

 

H6501IP-1 

Total solder points: 338 
Difficulty level: 

beginner

 1   2  3    4

advanced

 

Operate you

r appliances

 from 

anywhere w

ith a simple 

phone call.

 

Summary of Contents for K6501

Page 1: ...mote control by telephone K6501 ILLUSTRATED ASSEMBLY MANUAL H6501IP 1 Total solder points 338 Difficulty level beginner 1 2 3 4 5 advanced Operate your appliances from anywhere with a simple phone cal...

Page 2: ...put status Adjustable security code Pickup after 4 or 7 rings possible Room for three output relays one relay included Input to monitor the status of a switch from a distance Specifications Relay outp...

Page 3: ...he eyes Needle nose pliers for bending leads or to hold components in place Small blade and Phillips screwdrivers A basic range is fine For some projects a basic multi meter is required or might be ha...

Page 4: ...ts are cone shaped and shiny 3 Trim excess leads as close as possible to the solder joint REMOVE THEM FROM THE TAPE ONE AT A TIME AXIAL COMPONENTS ARE TAPED IN THE COR RECT MOUNTING SEQUENCE You will...

Page 5: ...4 7 2 B R19 100K 1 0 4 B R20 100K 1 0 4 B R21 100K 1 0 4 B R22 330K 3 3 4 B R23 390 3 9 1 B R24 390 3 9 1 B R25 390 3 9 1 B R26 820 8 2 1 B R27 820 8 2 1 B R28 820 8 2 1 B R29 820 8 2 1 B R30 2K2 2 2...

Page 6: ...F 104 C5 100nF 104 C6 100nF 104 C7 100nF 104 C8 100nF 104 C9 100nF 104 7 Capacitors Construction First Bend the leads exactly like the drawing Next Solder one lead and check the position if necessary...

Page 7: ...X 12 Quartz crystal SW1 1 pos 10 Push button VDR1 13 VDR C10 1 F C11 1 F C12 1 F C13 1 F C14 10 F C15 10 F 14 Electrolytic capacitors Watch the polarity C J1 2p J2 2p J3 2p J4 2p 16 Screw connectors...

Page 8: ...ion to the position of the notch 22 IC mounting PIN 1 1 C16 470 F 18 Electrolytic capacitor Watch the polarity C C17 0 47 F 250V 19 Capacitor VR1 UA7805 Check the orientation 20 Voltage regulator VR C...

Page 9: ...e switch is closed the green IN LED will light up 23 Connection Connection manual operation TEL LINE 12VAC 300mA LOAD1 LOAD2 LOAD3 SWITCH SWITCH OUT1 OUT2 OUT3 AC A B AC P6501 A B TEL LINE 1 The three...

Page 10: ...10 Code setting See table to set the first digit CODE1 or decades and the second digit CODE2 or units 25 Setting the code D C B A CODE1 SW2 0 1 2 3 4 5 6 7 8 9 SW2 CODE2 B A C D 9 8 7 6 5 4 3 2 1 0...

Page 11: ...ver you would like the device to pick up the phone sooner after 3 rings the manual operating push button should be held pressed before switching on the power supply Output 1 will switch on by way of c...

Page 12: ...you like SWITCHING A PARTICULAR OUTPUT ON Enter code1 code2 output number 1 After a few seconds you will hear the condition of the input and of the outputs Example Suppose you want to switch output 2...

Page 13: ...into a plastic housing e g our housing type D30 which will allow the LEDs and the push button to protrude through the front panel see figure for boreholes and board position After cutting out the LED...

Page 14: ...14 29 Schematic diagram Schematic diagram...

Page 15: ...15 PCB 30 PCB...

Page 16: ...5 4 1 0 3 2 9 2 8 9 4 3 0 Modifications and typographical errors reserved Velleman nv H6501IP 2004 ED1_rev 2 VELLEMAN NV Legen Heirweg 33 9890 Gavere Belgium Europe...