background image

Construction 

T

his code lock can be used to switch an alarm (e.g. car alarm 

K3504) on and off as well as to open a door lock. A LED on the 
operation panel reflects the state of the "lock". You can easily 
determine the code yourself. Thanks to its reduced dimensions, 
this code lock is very well suited to be built into a standard hous-
ing. Its fully closed operation panel allows it to be used inside as 
well as outside. 

 

 
 
 
 

 

 

 

 

q

SW1...SW9  

1. Push buttons

 

SW...

 

 
 
 
 

 

 

 
 
 

 
 
 

q

LD1 

2. Leds 

Watch the polarity !

 

COLOR= 2...5

LD...

CATHODE

 

T

he unit consist out of two PCB’s, one is the keyboard  

module “P6400S” and the other is the master module “P6400B”. 

 
 

F

irst we will start with the Keyboard module, then we assemble 

the master module. 
 

F

TIP

 :  The picture on the packaging can be used as a 

guideline. However, due to possible changes it is not 100% 
reliable.

 

Construction of P6400S

 

Summary of Contents for Velleman-Kit K6400

Page 1: ...2 Features More than 3000 codes possible State indication by LED Pulse or switch output Nine digits of which 4 code digits Secured against polarity reversal specifications Power supply 9 to 15VDC or...

Page 2: ...VELLEMAN Components NV Legen Heirweg 33 9890 Gavere Belgium http www velleman be http www velleman kit com...

Page 3: ...nose pliers for bending leads or to hold components in place Small blade and phillips screwdrivers A basic range is f fine For some projects a basic multi meter is required or might be handy 1 2 Assem...

Page 4: ...ace and carefully solder the leads Make sure the solder joints are cone shaped and shiny Trim excess leads as close as possible to the solder joint REMOVE THEM FROM THE TAPE ONE AT A TIME AXIAL COMPON...

Page 5: ...e Orange Orange Orange Orange Orange Oranje 3 4 Giallo Amarelo Amarillo Keltainen Gul Gul Gul Gelb Yellow Jaune Geel 4 5 Verde Verde Verde Vihre Gr n Gr n Gr nn Gr n Green Vert Groen 5 6 Blu Azul Azul...

Page 6: ...a standard hous ing Its fully closed operation panel allows it to be used inside as well as outside q SW1 SW9 1 Push buttons SW q LD1 2 Leds Watch the polarity COLOR 2 5 LD CATHODE The unit consist o...

Page 7: ...e code must be as close to the pcb as possible because other wise they will touch the aluminium front panel The code sequence is determined by connecting the lines A respectively B C and D to the conn...

Page 8: ...ated wires at the solder side of the pcb These wires will be used later on for through connection to the master module see fig 2 0 FAttention the wires at the component side must be cut off as close t...

Page 9: ...e input of the code the code lock will only generate a pulse in general this mode is used with door locks closed contact or open contact q NC or NO Fit wire jumper NC if you intend to use the normally...

Page 10: ...q T1 T2 BC547B or eq 5 Transistors q C1 10 F q C2 470 F 7 Electrolytic Capacitors Watch the polarity C Construction q D1 1N4148 or eq q D5 1N4000 q D2 D4 1N4148 or eq FThe side with the mark comes in...

Page 11: ...11 q IC1 CD4066 10 IC Check the position of the notch Construction q J2 2 x 2p 8 Screw connector q RY1 VR15M121C 9 Relay...

Page 12: ...module Take care that the LED is in the front panel Normally neither the LED nor the push buttons may pass through the front panel The push but tons must be flush with the front side Pass a 10mm dista...

Page 13: ...en you can cause the relay to open by entering a digit NOT belonging to the code digits G Tip should the opening time of the relay in the case of the pulse output mode be too short fit a 22 F ca pacit...

Page 14: ...14 P6400S Keyboard P6400B master PCB layout PCB...