VTSS110_v2
VELLEMAN
4
How to Clean a Tip?
•
Set the temperature to 250°C.
•
After the temperature has stabilized, clean the tip and check its condition. If the tip is deformed or badly worn,
replace it. If the solder-plated part of the tip is covered with black oxide, apply fresh solder containing flux and
clean the tip again.
•
Switch off the unit and remove the cooled tip with the heat-resistant pad. Remaining oxides such as the yellow
discoloration on the shaft can be cleaned with isopropyl alcohol. Store the tip in a cool and dry place.
Recalibrating the Soldering Iron
•
The soldering iron should be recalibrated each time you replace the soldering iron, heating element or tip.
•
Connect the unit to the mains.
•
Set the temperature control knob to 400°C.
•
Switch on the unit and wait for the temperature to stabilize. Remove the CAL pot plug.
•
After temperature stabilization, use a small Phillips-headed screwdriver and turn the CAL screw (clockwise to
increase, anticlockwise to decrease) until the tip thermometer reads 400°C. Replace the pot plug.
6. Troubleshooting
Problem Possible
Cause
Solution
The heater LED does not light
Not connected to the mains
Connect to the mains
Blown fuse
Determine the cause of the blown
fuse, replace the fuse
The heater LED lights but the tip
does not heat
Soldering iron cord defective
Have your dealer replace the cord
Defective heating element
Have your dealer replace the heating
element
The tip heats up intermittently
Oxidized or unclean tip
Clean the tip
Badly calibrated soldering iron
Recalibrate the soldering iron
Defective tip
Replace the tip
7. Technical Specifications
Power Supply
230VAC / 50Hz
Dimensions Station
187 x 128 x 246mm
Total Weight
5.8kg
Soldering Iron
Power Consumption
60W
Temperature Range
200°C ~ 480°C
Input Voltage
24V
Heating Element
PTC
Hot Air Gun
Power Consumption
450W
Temperature Range
100°C ~ 500°C
Air Capacity
23l/min
Heating Element
metal heating core
For more info concerning this product, please visit our website www.velleman.eu.
The information in this manual is subject to change without prior notice.
CAUTION: Disconnect the unit from the mains prior to examining and maintaining. Failure to