General Maintenance
Always shut off the soldering station and disconnect it from the mains before cleaning
and changing the soldering tip. Make sure the soldering iron has cooled down and has
reached room temperature; otherwise it can cause severe burns! Damage to the
soldering station may occur if the system is left on and the removed tip has not been
replaced.
•
Unscrew the coupling nut on the soldering iron and remove the soldering tip. Clean
off the rust, which may have formed in the cylinder. Never try to remove the
soldering tip during use (burn hazard). If the soldering tip should loosen during use,
turn off the soldering station and let the soldering iron cool down until it has
reached room temperature. Then tighten the coupling nut.
•
After removing the tip, you should blow out any oxide dust that may have formed in
the tip receptacle. Be careful not to get dust in your eyes. Replace the tip and
tighten the screw. Pliers can be used to avoid contact with hot surfaces BUT
SHOULD BE USED WITH CAUTION because over-tightening may cause damage to
the element or fuse the tip to the element.
•
The outer cover of the iron and station may be cleaned with a damp cloth using
small amounts of liquid detergent. Never submerse the unit in liquid or allow any
liquid to enter the case of the station. Never use any solvent to clean the case.
•
If the iron or station should become faulty or, for some reason does not operate
normally, the system should be returned to the service department of your
authorized dealer or service agent.
7.
Technical Specifications
input ................................................................................................ 230 V~, 50 Hz
output ......................................................................................................... 180 W
fuse ................................................................................................................ F1A
temperature range ............................................................ 100-500 °C (212-932 °F)
working temperature
melting point ........................................................................... 227 °C (440 °F)
normal operation......................................................... 300-360 °C (572-680 °F)
weight ........................................................................................................ 3.2 kg
dimensions .............................................................................. 166 x 100 x 150 mm
Use this device with original accessories only. Velleman nv cannot be held
responsible in the event of damage or injury resulting from (incorrect) use of
this device. For more info concerning this product and the latest version of this
manual, please visit our website www.hqpower.eu. The information in this
manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights
reserved.
No part of this manual may be copied, reproduced, translated or reduced to
any electronic medium or otherwise without the prior written consent of the copyright
holder.