hot air function 

17 

UP button (

) to increase temperature 

21 

SET button 

18 

DOWN button (

) to decrease temperature 

22 

UP button (

) to increase airflow 

19 

temperature display 

23 

airflow display 

20 

heating indication 

24 

DOWN button (

) to decrease airflow 

7.

 

Installation 

7.1

 

Installing the Fume Extractor 

This device comes with a fume extractor. Use this extractor always when soldering or desoldering. 

To install the fume extractor, proceed as follows: 

1.

 

Make sure that there is a filter in the device (see 

Replacing Filters

). 

2.

 

Place the extractor near the working area. 

3.

 

Plug the power cord into the back of the fume extractor, and plug the other end into a suitable main outlet. 

4.

 

Switch the extractor on. 

7.2

 

Installing the Rework Station 

 

Make sure that the operating voltage of the unit is identical to that of the electrical supply. 

 

In order to protect the pump during transportation, the pump in the machine is fixed by 4 screws in 
the base plate. You must unscrew the pump first; otherwise, you may damage the device 
permanently. 

 

Always place the irons and the hot air gun in their holders, even if the device is switched off or not 
in use. Do not place them on the table or any other surface. 

 

To install the rework station, proceed as follows: 

1.

 

Before the first use, remove the 4 screws in the base plate that protect the pump. Refer to the illustration 
below: 

 

2.

 

Place the device on a level, stable, and fire resistant working surface. 

3.

 

Screw the holder to the station. You can fit the holder on the left or right side: 

 

4.

 

Plug the soldering iron into the soldering iron connection 

[2]

 and place the iron in its holder. Note that the 

connector has a notch; it only fits in one way. Do not force. 

5.

 

Plug the desoldering iron into the desoldering iron connection 

[4]

, plug the vacuum tube to the VAC 

connection 

[5]

, and place the iron in its holder. Note that the connector has a notch; it only fits in one way. 

Do not force. 

6.

 

Plug the hot air gun into the hot air connection 

[6]

, and place the gun in its holder. 

7.

 

Make sure that the power switch 

[1]

 is in the off position (0). 

8.

 

Plug the power cord into a suitable, earthed mains outlet. 

Summary of Contents for VTSSD4

Page 1: ...VTSSD4 MULTI FUNCTION SMD REWORK STATION 100 W 600 W USER MANUAL...

Page 2: ...VTSSD4 V 01 15 05 2014 2 Velleman nv...

Page 3: ...evice is not in use or when servicing or maintenance activities are performed Handle the power cord by the plug only Caution After switching off leave the power cord plugged in for a few minutes When...

Page 4: ...tion line The zero voltage switching design protects voltage and current sensitive components such as CMOS devices against overcurrent and transient voltage spikes Delayed suction to prevent solder fr...

Page 5: ...the device at higher temperatures for short periods but this will shorten the lifespan of the tip Desoldering Recommended tip temperatures for desoldering are detailed below They can vary from joint...

Page 6: ...plate You must unscrew the pump first otherwise you may damage the device permanently Always place the irons and the hot air gun in their holders even if the device is switched off or not in use Do no...

Page 7: ...ode temperature indication The display shows F 0 3 Press the or button to select a mode If you do not press a button within 15 seconds the device returns to normal operation mode F 0 exit menu mode Pr...

Page 8: ...with a new tip let the station idle for three minutes at 250 C 482 F 5 Set the irons to the desired working temperature 6 Always return the soldering irons to their stand between uses Important Desol...

Page 9: ...e Causes of Loss of Suction Use the procedure outlined below to determine whether the loss of suction is due to the tip to the solder collector the tube or the in line filters Warning Set the power sw...

Page 10: ...stopped and then disconnect the power cord 2 Wait until both heater and nozzle are completely cold 3 Select the nozzle that matches the IC size 4 Loosen the screw on the nozzle slide the nozzle on the...

Page 11: ...3 Cleaning Clogged Tips To prevent solder from clogging the desoldering tip clean the desoldering tip after each use with the included spring wire This increases the tip life Proceed with care when r...

Page 12: ...p the station in proper working order 5 Remove the cooling strip with a pair of pliers 6 Clean the cooling strip and collector with a wire brush included 11 5 Replacing Filters Notes Never attempt to...

Page 13: ...at holds the filter in place push the protrusions b inward and remove the grid from between the fume extractor side flaps c 3 Remove the old filter d and place a new one in front of the ventilator e 4...

Page 14: ...soldering iron VTSSC7 SP5 spare cleaning pin VTSSD SP2 barrel and nut assembly for soldering iron VTSSC7 SP4 barrel and nut assembly for desoldering iron VTSSD3 SP2 desoldering iron heater VTSSD3 SP1...

Page 15: ...hocks falls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits consumable goods parts or accessories that are subject to an aging process duri...

Reviews:

Related manuals for VTSSD4