Switching On and Off 

 

To switch the device on, set the power switch 

[1]

 in the on position (1). The switch lights up. The device 

activates all functions (soldering, desoldering, and hot air) and starts heating up. The heating 
indications 

[10,15,20]

 light up during warming up. The displays 

[9,14,19]

 show the temperature. 

 

To switch the device off, set the power switch 

[1]

 in the off position (0). 

Caution!

 After switching off, 

leave the power cord plugged in

 for a few minutes. When you switch off the 

unit, the automatic cooling function blows cooling air through the heater pipe for a short period. This protects 
the heater from damage and extends its lifetime. Do not disconnect the mains plug during this cooling process. 

Wait until the cooling process has stopped, then disconnect the power plug. The device uses a small amount of 
electrical power, even if it is switched off. 

Switching off Individual Functions 

When you switch on the device, it activates all functions: soldering, desoldering, and hot air. However, to save 
power, you can switch off individual functions. Proceed as follows: 

1.

 

To switch off a function, press the corresponding SET and 

 buttons simultaneously. For example, to switch 

off desoldering, press buttons 

[16]

 and 

[13]

. The corresponding temperature display shows 

“—

 

 

—”

2.

 

To reactivate a function, press the corresponding 

 button. 

9.

 

Using the Soldering/Desoldering Iron 

9.1

 

Parameter Settings 

The parameter settings for soldering and desoldering are identical. Use the buttons that correspond with the 
function that you want to set. For soldering, use buttons 7

11. For desoldering, use buttons 12

16. 

1.

 

Switch on the station 

[1]

2.

 

Press and hold the SET button for at least 5 

seconds until “—

 

 

—” flashes on the display. Use t

he 

 button 

to enter the password “010” (default) and press the SET button to enter the setup menu. An 

incorrect password will return the station to normal operation mode (temperature indication). 

The display shows “F

-

0”.

 

3.

 

Press the 

▲ 

or 

 button to select a mode. If you do not press a button within 15 seconds, the device 

returns to normal operation mode. 

 

 

F-0

: exit menu mode 

Press the SET button when the display shows F-0 to exit the setup menu and return to normal operation 
mode. 

 

F-1

: password mode 

If password mode is enabled, you cannot change the temperature settings on the station unless you know 
the password. 
Press the SET button once to enter password mode. Press the 

 or 

 button to switch between 000 

(password mode disabled) and 100 (password enabled). Press the SET button to return to the setup menu. 

 

F-2

: temperature correction mode 

If the displayed temperature deviates from the actual temperature of the tip, you can calibrate the display 
here. 
Press the SET button once to enter temperature correction mode. Press the 

 or 

 button to enter a 

correction factor for the temperature (

99 °C to +99 °C; 

178 °F to +178 °F). For example, if the display 

shows 300 °C but the actual temperature is only 290 °C, add 10 °C to the shown correction value. If the 
current correction value is 00, change it to 10. If the current correction value is 

20, set it to 

10. If the 

current correction value is 20, set it to 30. 
A minus sign in front indicates a negative value. Press the SET button to return to the setup menu. 

 

F-3

: sleep/power off mode 

If you enable the sleep/power off mode, the device automatically lowers the iron temperature after 
20 minutes of inactivity (sleep mode). After 40 minutes of inactivity, the power to the iron is shut off 
(power off mode). 

Note:

 you can set the sleep/power off mode individually for the soldering and desoldering iron. 

Press the SET button once to enter sleep/power off mode. Press the 

 or 

 button to switch between 000 

(sleep/power off mode disabled) and 100 (sleep/power off mode enabled). Press the SET button to return 
to the setup menu. 
In sleep mode, the device lowers the soldering iron temperature to 150 °C (302 °F), and the desoldering 
iron temperature to 200 °C (392 °F). The display flashes and shows the lowered temperature. 

Note:

 by default, sleep/power mode is disabled. 

Summary of Contents for VTSSD4

Page 1: ...VTSSD4 MULTI FUNCTION SMD REWORK STATION 100 W 600 W USER MANUAL...

Page 2: ...VTSSD4 V 01 15 05 2014 2 Velleman nv...

Page 3: ...evice is not in use or when servicing or maintenance activities are performed Handle the power cord by the plug only Caution After switching off leave the power cord plugged in for a few minutes When...

Page 4: ...tion line The zero voltage switching design protects voltage and current sensitive components such as CMOS devices against overcurrent and transient voltage spikes Delayed suction to prevent solder fr...

Page 5: ...the device at higher temperatures for short periods but this will shorten the lifespan of the tip Desoldering Recommended tip temperatures for desoldering are detailed below They can vary from joint...

Page 6: ...plate You must unscrew the pump first otherwise you may damage the device permanently Always place the irons and the hot air gun in their holders even if the device is switched off or not in use Do no...

Page 7: ...ode temperature indication The display shows F 0 3 Press the or button to select a mode If you do not press a button within 15 seconds the device returns to normal operation mode F 0 exit menu mode Pr...

Page 8: ...with a new tip let the station idle for three minutes at 250 C 482 F 5 Set the irons to the desired working temperature 6 Always return the soldering irons to their stand between uses Important Desol...

Page 9: ...e Causes of Loss of Suction Use the procedure outlined below to determine whether the loss of suction is due to the tip to the solder collector the tube or the in line filters Warning Set the power sw...

Page 10: ...stopped and then disconnect the power cord 2 Wait until both heater and nozzle are completely cold 3 Select the nozzle that matches the IC size 4 Loosen the screw on the nozzle slide the nozzle on the...

Page 11: ...3 Cleaning Clogged Tips To prevent solder from clogging the desoldering tip clean the desoldering tip after each use with the included spring wire This increases the tip life Proceed with care when r...

Page 12: ...p the station in proper working order 5 Remove the cooling strip with a pair of pliers 6 Clean the cooling strip and collector with a wire brush included 11 5 Replacing Filters Notes Never attempt to...

Page 13: ...at holds the filter in place push the protrusions b inward and remove the grid from between the fume extractor side flaps c 3 Remove the old filter d and place a new one in front of the ventilator e 4...

Page 14: ...soldering iron VTSSC7 SP5 spare cleaning pin VTSSD SP2 barrel and nut assembly for soldering iron VTSSC7 SP4 barrel and nut assembly for desoldering iron VTSSD3 SP2 desoldering iron heater VTSSD3 SP1...

Page 15: ...hocks falls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits consumable goods parts or accessories that are subject to an aging process duri...

Reviews: