55
110331-03 - 1/22
PHTM II
Combi Installation, Operating & Service Instructions
16
Operation
(continued)
Press "
" or "
" buttons to switch between menus
A
,
b
,
C
, and
PAS
, press "
enter
" to Select. The following items
are available in the
A
menu.
Menu
AA
,, Quick Menu
Table 16-8: Quick Menu (with no password entered)
Display
Range
Description
A01
On/Off
Boiler On/Off Switch
A02
On/Off
DHW Comfort Mode
A03
60 -140°F
(16 - 60°C)
DHW Setpoint
A04
60 - 190°F
(16 - 88°C)
Central Heat 1 Setpoint
A05
60 -190°F
(16 - 88°C)
Central Heat 2 Setpoint
A01
A01
Boiler Switch
Allows an installer to prevent boiler starts while
reviewing boiler settings.
A02
A02
DHW Comfort Mode
DHW Comfort Mode monitors recirculation sensor and
controls a recirculation pump wired to Auxiliary Pump
terminals. Comfort mode helps keep water warm to be
immediately available at fixtures.
A03
A03
DHW Setpoint
Desired temperature of DHW produced by boiler.
A04
A04
Central Heating 1 Setpoint
Desired water temperature of Central Heat 1 (CH1).
A05
A05
Central Heating 2 Setpoint
Desired water temperature of Central Heat 2 (CH2).
Menu
bb
, Lockout/Hold History Menu
Figure 16-7: Adjusting Parameters
Menu
cc
,, Diagnostic Menu
Table 16-9: Diagnostic Menu
Display
Description
C01
Active Detailed Fault Code (see Table 19-6)
C02
Demand Source
1 Standby
2 Central Heat 1
3 Central Heat 2
4 Domestic Hot Water
5 Sequencer Control
6 CH Frost Protection
7 DHW Frost Protection
8 Boiler On/Off Switch
9 Warm Weather Shutdown
C03
Fan Speed Demanded (RPM x 100)
C04
Fan Speed Feedback (RPM x 100)
C05
Three Way Valve Status (0) DHW, (1) CH
C06
System Pump On/Off Status
C07
Boiler Pump On/Off Status
C08
Auxiliary Pump On/Off Status
C09
Flame Signal
C10
Safety Software Revision
C11
Application Software Revision
C12
Parameter Revision
C13
Boiler Size Status: (1) 136 combi
(2) 200 combi
(3) 080 heat only
(4) 120 heat only
(5) 150 heat only
(6) 180 heat only
+
–
Press to select menu or
parameter to edit.
Press buttons
to view next
menu or
parameter.
Press
buttons
to adjust
parameters.
b01
to
b08
are Lockout or Hold history records.
b01
is
latest entry.
Adjust Mode Menu
Diagnostic information and Quick Menu parameters are available without entering a password. Press and Hold
“
menu
” button for 3 seconds to access Adjust Mode.
Press and hold for three seconds
to access Adjust Mode
Press to exit current menu or
cancel current editing session
reset