45
106309-03 - 4/19
Boiler Model
Supply
& Return
Connection
(in.)
Near
Boiler
Pipe Size
(in.)
D
T=35°F
D
T=30°F
D
T=25°F
D
T=20°F
Flow
(GPM)
Boiler &
Piping
Head Loss
(ft.)
Circulator
Model
Flow
(GPM)
Boiler &
Piping
Head Loss
(ft.)
Circulator
Model
Flow
(GPM)
Boiler &
Piping
Head Loss
(ft.)
Circulator
Model
Flow
(GPM)
Boiler &
Piping
Head Loss
(ft.)
Circulator
Model
PHNTM399C
1½
2
21.5
6.4
UP26-64F
25.1
8.4
UP26-99F
30.2
1
1.5
UPS43-100F
,
Spd. 2
37.7
16.9
UPS43-100F
,
Spd. 3
PHNTM500C
2
2
27.7
5.8
UPS43-44FC,
Spd. 2
32.3
7.5
UPS43-44F
38.8
10.3
UPS43-100F
,
Spd. 2
48.5
15.2
UP50-60F
,
Spd. 3
PHNTM600C
2
2
33.9
5.5
UPS43-44FC,
Spd. 3
39.6
7.2
UPS43-100F
,
Spd. 2
47.5
9.9
UPS50-60F
,
Spd. 2
59.4
14.7
UPS40-80/2,
Spd.3
PHNTM700C
2
2
39.4
7.1
UPS43-100F
,
Spd. 2
45.9
9.4
UPS43-100F
,
Spd. 3
55.1
12.9
UPS50-60F
,
Spd. 3
68.9
19.1
UP50-80/2,
Spd. 3
PHNTM800C
2
2
1
/
2
43.4
6.4
UPS43-100F
,
Spd.2
50.7
8.5
UPS43-100F
,
Spd. 3
60.8
1
1.8
UP-50-60F
,
Spd. 3
76.0
17.6
UPS50-80/2,
Spd. 3
Table 25: Recommended T
aco Circulators for 50 ft. Equivalent ft. Near Boiler Piping [Approximately 20 ft.
Straight Pipe, (4) 90° Elbows, and (2) Full Port Ball V
alves]
Boiler Model
Supply
& Return
Co
n
n
ect
io
n
(in.)
Near Boiler
Pipe Size
(in.)
D
T=35°F
D
T=30°F
D
T=25°F
D
T=20°F
Flow
(GPM)
Boiler &
Piping
Head Loss
(ft.)
Circulator
Model
Flow
(GPM)
Boiler &
Piping
Head Loss
(ft.)
Circulator
Model
Flow
(GPM)
Boiler &
Piping
Head Loss
(ft.)
Circulator
Model
Flow
(GPM)
Boiler &
Piping
Head Loss
(ft.)
Circulator
Model
PHNTM399C
1½
2
21.4
6.4
0014
25.0
8.3
0013
30.0
1
1.4
2400-60
37.5
16.8
2400-70
PHNTM500C
2
2
27.7
5.8
0012
32.3
7.5
2400-60
38.8
10.3
2400-60
48.5
15.2
2400-65
PHNTM600C
2
2
33.9
5.5
2400-60
39.6
7.2
2400-60
47.5
9.9
2400-65
59.4
14.7
2400-70
PHNTM700C
2
2
39.4
7.1
2400-60
45.9
9.4
2400-65
55.1
12.9
2400-65
68.9
19.1
1935
PHNTM800C
2
2
1
/
2
43.4
6.4
2400-60
50.7
8.5
2400-65
60.8
1
1.8
2400-65
76.0
17.6
1935
VI. W
ater Piping and T
rim
(continued)
Table 26: Recommended Grundfos Circulators for 50 Equivalent ft. Near Boiler Piping [Approximately 20 ft.
Straight Pipe, (4) 90° Elbows, and (2) Full Port Ball V
alves]
Summary of Contents for Phantom-X Series
Page 49: ...49 106309 03 4 19 VI Water Piping and Trim continued Figure 28 Near Boiler Piping Heating Only...
Page 63: ...63 106309 03 4 19 VIII Electrical continued Figure 40 Ladder Diagram...
Page 64: ...64 106309 03 4 19 VIII Electrical continued Figure 41 Wiring Connections Diagram 2...
Page 73: ...73 106309 03 4 19 IX System Start up continued Figure 47 Operating Instructions...
Page 124: ...124 106309 03 4 19 XIII Service Parts continued...
Page 130: ...130 106309 03 4 19 XIII Service Parts continued...
Page 133: ...133 106309 03 4 19 XIII Service Parts continued 10A 10B 10C 10D 10G...
Page 139: ...139 106309 03 4 19...