X. Operation
E. Boiler Sequence Of Operation (continued)
2. Using The Display
The Control includes a touch screen LCD display. The user monitors and adjusts boiler operation by selecting screen
navigation “buttons” and symbols. The “Home Screen” and menu selections are shown below. When no selection is
made, while viewing any screen, the display reverts to the “Home Screen” after 4 minutes. The “Home Screen” provides
boiler temperature, firing rate in BTU/hr, boiler status, efficiency information and page links.
Rate
Firing rate is displayed as kbtu/hr input.
Demand Status
The reason or cause of the boiler demand is
displayed; Central Heat, Auxiliary Heat, Domestic
Hot Water, Sequencer Control (peer-to-peer
Demand) or Frost Protection. Warm Weather
Shutdown status is shown. “Standby’ is shown
when no demand is present.
Energy Save On Indication
Outdoor Air Reset, DHW or setback have lowered
boiler water setpoint.
High Efficiency On Indication
Return temperature is low enough to allow energy
saving flue gas condensation.
Menu Buttons
The Home Screen Menu Buttons
connect the displays four main display
groups:
Information Symbol
“Information” symbol links most
screens to screen content
explanations. New terminology used
in status and adjustment screens are
explained in plain words.
Fault Indication
In the event of a boiler fault the screen
color turns red and the user is guided
by “blinking” touch buttons to Help
screens that explain the problem
cause and corrective action.
Figure 50: Home Screen Details
Figure 51: Screen Navigation
Close Symbol
The “Close” symbol returns to the display to previous menu or screen.
Repeatedly pressing the “Close” symbol will always return the display
to the “Home” screen.
Arrow Symbol
The “Arrow” symbol links together all screens in the selected group.
For example, repeated pressing the right “Arrow” symbol will rotate
the display around all the screens in the Status group. Using this
feature the user can review all the boiler status and adjustment mode
screens.
Fault Symbols
“Active Fault” and “Rate Limit”
symbols provide a link to the cause
of a boiler fault or firing rate limit. The first boiler status screen
provides an overview of boiler operation including fault status.
Status Screen
Summary of Contents for Phantom-X Series
Page 49: ...49 106309 03 4 19 VI Water Piping and Trim continued Figure 28 Near Boiler Piping Heating Only...
Page 63: ...63 106309 03 4 19 VIII Electrical continued Figure 40 Ladder Diagram...
Page 64: ...64 106309 03 4 19 VIII Electrical continued Figure 41 Wiring Connections Diagram 2...
Page 73: ...73 106309 03 4 19 IX System Start up continued Figure 47 Operating Instructions...
Page 124: ...124 106309 03 4 19 XIII Service Parts continued...
Page 130: ...130 106309 03 4 19 XIII Service Parts continued...
Page 133: ...133 106309 03 4 19 XIII Service Parts continued 10A 10B 10C 10D 10G...
Page 139: ...139 106309 03 4 19...