21
Speed vs. color code for *CTM Motor:
Low = Red
Med-Low = Purple
Medium = Blue
Med-High = Yellow
High = Black
*CTM is an abbreviation for Constant Torque Motor
M. BLOWER CONTROLLER INFORMATION FOR PSC AND CTM MOTOR
TERMINAL DEFINITIONS & FIELD WIRING
Burner Harness Connector P1
Pin 1- Limit switch connector.
Pin 2- 120 VAC Line connection.
Pin 3- Burner pilot contact.
Pin 4&5-
120 VAC Neutral connections.
Pin 6- Burner pilot contact.
Pin 7&8-
From oil primary control.
Pin 9- Limit Switch Input (LSI).
Field Wiring to Burner
Harness Wires
Beckett Connections
Riello Connections
Thermostat / Humidistat connections
“C”
Common / ground
“W”
Thermostat call for heat
“R”
24 VAC to thermostat
“G”
Thermostat call for fan
“Y”
Thermostat call for cool
“DEHUM”
Humidistat call for dehumidification (TXV systems ONLY)
Male quick connect terminals.
“S1-3”
120 VAC Hot
“N1-7”
120 VAC Neutral
“EAC”
Electronic Air Cleaner (120 VAC) connection
“FAN”
Fan On Signal
“X”
24 VAC from transformer
“C”
24 VAC common from transformer
“CC”
Compressor Contactor
“CC_COM”
Compressor Contactor Common
“LOW”
Continuous Blower Speed
“HEAT”
Blower heat speed tap
“COOL”
Blower cool speed tap
Pilot (Tstat) Neutral Line
Yellow Wires
White
Red
T-T terminals
White
Black
T-stat terminals
White
Black
Summary of Contents for VCH8FA119P60B
Page 4: ...2...
Page 34: ...32 V Sequence of Operations Flow Chart...
Page 35: ...33...
Page 36: ...34 VI Trouble Shooting Flow Chart...
Page 37: ...35...
Page 38: ...36...
Page 39: ...37...
Page 40: ...38...
Page 42: ...40 Appendix A Replacement Parts for VCH8FA119...
Page 43: ...41...
Page 44: ...42 Appendix B VCH8FA119P60 PSC Wiring Diagram...