background image

 INSTALLATION 

MANUAL

V 1.05

Summary of Contents for LITE Zero

Page 1: ...INSTALLATION MANUAL V 1 05...

Page 2: ...ED IN THE PACKAGING 6 2 4 REQUIRED TOOLS 7 3 INSTALLATION 3 1 INSTALLATION OF THE LITE ZERO UNO KUBO CHARGE 8 3 2 INSTALLATION OF THE STAND ELEMENT 16 3 3 INSTALLATION OF THE CURVE DEVICE 19 3 4 INSTA...

Page 3: ...riginal manual is written in Spanish Translation of the original manual into different languages has the sole purpose of clarifying its content In the event of discrepancy between the translated docum...

Page 4: ...nces Do not use extension cables or adapters for the charging cable The charger must always be connected to the installation s ground connection Do not install the charger near inflammable explosive o...

Page 5: ...NSTALLATION MANUAL 2 BEFORE STARTING 2 1 IDENTIFICATION OF THE CHARGER The charger model is visible on its cover LITE Zero Uno or Kubo The charger also comes with a label on the side indicating its mo...

Page 6: ...late for installation 1 Cable holder 1 2 2 ELEMENTS INCLUDED IN THE PACKAGING 2 BEFORE STARTING 2 3 OPTIONAL ACCESSORIES ELEMENT QUANTITY STAND STAND 1 M5x12 screw 1 single STAND 2 double STAND M5x70...

Page 7: ...OOLS LITE Zero Uno Kubo Driller 8 mm bit Phillips PH2 screwdriver Hammer Pencil or marker STAND Spanner 4 mm Allen or hex key CURVE 3 2 mm flathead screwdriver SINGLE PHASE METER SET Phillips PH1 scre...

Page 8: ...CURVE DEVICE OPTIONAL If you are going to connect the charger to a single phase or three phase meter a communications device modem router switch or to another charger check that the Ethernet wiring f...

Page 9: ...in the desired position approximately 1 2 m from the horizontal reference to the ground 4 PLACE THE TEMPLATE 1 2 m Ground Connector height 3 INSTALLATION We recommend that you use a spirit level to en...

Page 10: ...the indicated height 2 Cut and strip the cables to the recommended length 3 Fit the ferrules 20 mm hollow crimp ferrule 5 5 cm Connection tube 25 cm Lite Zero Uno 20 mm hollow crimp ferrule 5 5 cm Con...

Page 11: ...the holes 3 Fit the wall plugs Insert the screw of the upper part and tighten it into the bushing as far as it will go 7 FIT THE UPPER SCREW Wall mounting 4 8x38 screw STAND assembly M5x12 screw 3 INS...

Page 12: ...ATION OF THE CURVE DEVICE OPTIONAL If you are going to connect the charger to a single phase or three phase energy meter a communications device modem router switch or to another charger check that th...

Page 13: ...l the SINGLE PHASE OR THREE PHASE METER SET see item 3 4 INSTALLATION OF THE SINGLE PHASE AND THREE PHASE METER SET 11 OPTIONAL CONNECTION OF THE CHARGER TO ANOTHER CHARGER OR TO A COMMUNICATIONS ELEM...

Page 14: ...hem firmly 2 Fit the caps to cover the three screws 13 FIX THE CHARGER TO THE WALL 14 INSTALL THE CHARGING CABLE SUPPORT 1 Mark the holes to be made in the wall 2 Drill the holes 3 Fit the wall plugs...

Page 15: ...15 INSTALLATION MANUAL 15 SUPPLY POWER TO THE CHARGER Close the element that cuts off the electrical circuit powering the charger 4 Fit the screws 3 INSTALLATION...

Page 16: ...N OF THE STAND ELEMENT 1 Prepare the ground anchors for the STAND element according to the figure always using M12 components 20 5 cm 15 5 cm 2 Remove the top part of the STAND element in order to acc...

Page 17: ...nd and pass the power supply cables and the auxiliary wiring for connecting other devices through the hollow interior from the bottom until they can be pulled out through the corresponding grommet Aux...

Page 18: ...rs to be used in this case must be those provided with the STAND element and not those supplied with the charger Given that in this case the power supply does not come through the side of the charger...

Page 19: ...re general or home Connection cables with charger Active phase 3 INSTALLATION The CURVE device is designed for use with the LITE Zero Uno charger Operation of the CURVE device is independent from the...

Page 20: ...5 two cable wire between the CURVE device and the charger 5 Strip 8 mm from each wire of the cable and connect it to the terminals of the CURVE device 8 mm 6 Strip 8 mm from each wire of the cable an...

Page 21: ...to communicate by means of infrared signals 3 Strip the power cables 10 mm and the neutral cable 8 mm 3 INSTALLATION The METER SET is made up of two elements an energy meter and a smart gateway At th...

Page 22: ...to the latter place the power and neutral cable contacts in the smart gateway and tighten the screws 3 INSTALLATION The incorrect or incomplete connection of voltage or other terminals can cause malfu...

Page 23: ...ON MANUAL 6 Run an Ethernet cable with RJ45 connectors on both ends and connect it to both the smart gateway and the charger Connect it to either of the charger s two RJ45 sockets LITE Uno LITE Kubo 3...

Page 24: ...ASE AND THREE PHASE METER SET the following Connect the charger to a communications device modem router switch The communications device can be connected to either of the two sockets interchangeably C...

Page 25: ...e charger or group of chargers with three phase meter Charge scheduling Yes No of EV that can be charged simultaneously 1 Integration with photovoltaic generation No Yes Solar Mode Mixed Mode Electric...

Page 26: ...K10 Plug holder tethered cable model Integrated to the unit Cable length tethered cable model 5 meters 7 meters Power supply connection Accessible from the exterior no need to open the charger during...

Page 27: ...27 INSTALLATION MANUAL 4 TECHNICAL SPECIFICATIONS 220 mm 365 mm 105 mm 138 mm 45 mm 120 mm DIMENSIONS...

Page 28: ...argers Double STAND 2 Mechanical Material Lacquered steel Single STAND dimensions mm 1400 x 283 x 240 Double STAND dimensions mm 1400 x 310 x 350 Single STAND weight 25 kg Double STAND weight 26 5 kg...

Page 29: ...ECHNICAL SPECIFICATIONS 27 mm 48 mm 57 mm 22 mm TECHNICAL SPECIFICATIONS Electrical Maximum current 63 A Mechanical Dimensions mm 48 x 57 x 27 Material PC ABS V0 Maximum cable gauge 25 mm2 Charger lin...

Page 30: ...Dimensions mm 36 x 90 x 64 Mounting DIN rail Electrical Power supply Single phase P N Maximum current 65 A Voltage 230 V AC Frequency 50 60 Hz Cable gauge 1 5 16 mm2 Certification MID Images taken fro...

Page 31: ...ECHNICAL SPECIFICATIONS Smart gateway SG E1 Mechanical Dimensions mm 17 5 x 95 4 x 68 2 Mounting DIN rail Electrical Power supply Single phase P N Voltage 85 265 V AC Cable gauge 0 5 3 mm2 Communicati...

Page 32: ...l Electrical Power supply Three phase 3P N Maximum current 80 A Voltage 3 x 400 V AC Frequency 50 60 Hz Phase cable gauge 2 5 25 mm2 Neutral cable gauge 0 5 1 5 mm2 Certification MID Images taken from...

Page 33: ...NICAL SPECIFICATIONS Smart gateway SG E1 Mechanical Dimensions mm 17 5 x 95 4 x 68 2 Mounting DIN rail Electrical Power supply Single phase P N Voltage 85 265 V AC Cable gauge 0 5 3 mm2 Communications...

Page 34: ...VELTIUM Smart Chargers S L Parque Tecnol gico de lava c Albert Einstein 30 01510 Vitoria Spain Tel 34 945 297 271 Email info veltium com www veltium com...

Reviews: