System settings

A

Enter

Back

A B C D E F G

H

 Register products 

 

Select products

 Security key

SySTEM SETTINGS

Back

AuTO SET-uP

Back

INFORMATION

New products 

registered

B

A

AuTO SET-uP

INFORMATION

New products 

registered

Enter

Back

A B C D E F G

H

 Register products 

 

Select products

 Security key

SySTEM SETTINGS

Back

Back

 

 

H

 Registration from a new product

 

 New products can be registered directly in the interface/
repeater unit . 

 

 The example shows how to prepare VELUX products for 
registration.

 

Step 1: Product B

 Switch off mains power to the product for at least one 
minute and subsequently switch on again.

 

 Note:

 For other types of products, please refer to the ins-

tructions provided with the product in question to execute 
step 1.

 

Step 2: Interface/repeater unit A 

 Menu item 

H

 is highlighted.

 

 Press 

   to highlight "Register products".

Press 

 "Enter" to confirm your choice.

 Automatic registration is running. Please wait. The regis-
tration can take up to two minutes.

 The display shows that the new product(s) has/have been 
registered.

 

Step 1:KLI 110

 

 Transmit system from KLI by pressing the "PRG" button 
for 3-4 seconds. LED flashes green slowly.

 

Step 2: Interface/repeater unit A

1

 

 Menu item 

H

 is highlighted.

 

 Press 

   to highlight "Register products".

Press 

 "Enter" to confirm your choice.

2

 

 Automatic registration is running. Please wait. The regis-
tration can take up to two minutes.

3

 

 The display shows that the new product(s) has/have been 
registered.

 

 

Connection to entries

 

 A single contact can be used for running products either 
up or down. A set of two contacts can be used for running 
products both up and down with variable stops.

 

 A change-over contact can also be used for running pro-
ducts both up and down but stops are not possible.

 

 Contact requirements

 

 Dry contacts with a maximum resistance of 100 Ù can 
be used. A current of 5-10 mA at approx 10 V d.c. runs 
through the contact.

 

 Contacts with a pulse signal can also be used if the dura-
tion of the pulse is longer than 100 ms.

 

 

Note:

 The operation of the interface/repeater unit can 

only be stopped by switching off the mains power.

Summary of Contents for KLF 100

Page 1: ...VAS 452421 2010 03 KLF 100 ENGLISH User manual ESPA OL Manual de usario FRAN AIS Notice d utilisation JAPANESE...

Page 2: ...2 VELUX VELUX 3 English User manual x x Espa ol Manual del usuario x x Fran ais Notice d utilisation x x Japanese User manual x x...

Page 3: ...t function and connection 14 15 Settings Channels 16 19 Set channel 16 Block channel 17 Permanent blocking 18 19 Setting of position 20 21 Position UP 21 Position DOWN 21 System settings Register prod...

Page 4: ...s The interface repeater unit can be used as a repeater that extends the operation range of remote controls in the system Product The interface repeater unit is used when products are to be controlled...

Page 5: ...e disposed of in conformity with the relevant environmental regulations and ordinances The packaging can be disposed of with usual household waste Radio frequency band 2 4 GHz Radio frequency range 11...

Page 6: ...is switched on After a short time menu item A is displayed A Language 1 Press to highlight your language Press Enter to confirm your choice 2 The display shows that the language has been saved After...

Page 7: ...ucts described on pages 26 27 It is not necessary to go through the other submenus in menu item H The interface is now ready for use Thermostatic control of a VELUX skylight by a compa tible thermosta...

Page 8: ...ire required CLOSE DOWN OFF is controlled by connecting C and 2 core wire required STOP is controlled by connecting C with both and 3 core wire required Note Alternatively a single contact can control...

Page 9: ...ecommended to choose channel 7 1 Press to choose channel Press Enter to confirm your choice 2 The display shows that the chosen channel has been saved After a short time menu item D is displayed D Blo...

Page 10: ...activating entry and entry from the external control device The blocking can also be cancelled temporarily by pressing Menu on the display of the interface The next time the entries are activated the...

Page 11: ...ponds to the display information on a VELUX remote control This applies to all product types except Skylight You are therefore recommended to use the position table when setting the position Always ch...

Page 12: ...efore proceeding H Registration from a remote control If you have a VELUX remote control you can copy the registered products from the remote control to the inter face repeater unit Note All products...

Page 13: ...regis tration can take up to two minutes 4 The display shows that the new product s has have been registered Step 1 KLI 110 Transmit system from KLI by pressing the PRG button for 3 4 seconds LED flas...

Page 14: ...our choice The display shows a list of all registered products 3 Press to highlight the product to be edited Press Edit to confirm that the product in question is to be edited 4 Press to highlight Sel...

Page 15: ...to confirm your choice 2 Press to highlight Change Press Enter to confirm your choice The display now indicates that the security key has been changed 3 The display asks whether the security key of ot...

Page 16: ...istered directly in the interface repeater unit as shown on page 23 they can be copied to other interface repeater unit or remote controls The copying takes place in 2 steps Step 2 must be completed w...

Page 17: ...one and the same entry Each time the entry is activated the function will change For instance ordinary electric light in buildings is contro lled from a wall switch that turns the light both on and of...

Page 18: ...confirm your choice 2 The display shows that the repeater function has been activated Press Continue to open for registration 3 The display shows that the repeater function is ready to be registered...

Page 19: ...peater unit With two outputs it is possible to control both of the functions and in an product or a group of products You can control up to 200 products or groups of products individually Howe ver ind...

Page 20: ......

Reviews: