HP10E / HP12E / HP15E / HP20E - Dairy design
6. Graphical control
6-72
© VEMAG 2013
Number
Message
Cause
Remedy
920
Twist drive application
Fault in the application module.
This fault occurs in combination
with other fault numbers.
Note the numbers of all current
faults and contact VEMAG Service.
922
Main drive manual
Main drive operated manually.
Release manual drive button S10.
923
Twist drive manual
Twist drive operated manually.
Release manual drive button S9.
924
Infeed drive manual
Feed unit drive operated manually. Release manual drive button S10.
925
Blade drive timeout
The reference movement of the
machine‘s internal blade drive took
too long.
Check the reference sensor and
the blade drive‘s application
module. Make a note of the error
number and inform the VEMAG
Customer Service team.
929
Belt drive not found
Belt drive not found on CAN bus.
Check power supply at drive con-
troller FU4 and that the CAN bus
lines are correctly wired.
931
Communication belt drive
CAN bus communication with belt
drive interrupted.
Check that CAN bus line is wired
correctly.
932
Unexpected belt drive
Unconfigured belt drive found on
CAN bus.
Activate the belt drive in the PC
if necessary.
933
Belt drive inhibit
Controller for belt drive not
released.
Check controller release at FU4,
terminal 31.
935
Belt drive manual
Belt drive operated manually.
Release manual drive button.
937
Blade drive timeout
The machine‘s internal blade drive
took too long to reach its starting
position.
Check the reference sensor and
the blade drive‘s application
module. Make a note of the error
number and inform the VEMAG
Customer Service team.
940
Attachment 2 ready
Attachment 2 is ready (e.g. han-
ging machine).
-
942
External drive 1 not found The PC could not find the first
drive controller from attachment 2
on the CAN bus.
Check the power supply of the
first drive controller and that the
external CAN bus has been wired
correctly (con socket).
943
External drive 1 commu-
nication
CAN bus communication to the
first drive controller of attachment
2 was interrupted.
Check that the CAN bus has been
wired correctly.
944
No release for external
drive 1
The first drive of attachment 2 is
not released.
Check the voltage on terminal 31.
945
External drive 1 applica-
tion error
There is a communication error
between the application module
of attachment 2 and A1 (PC). This
error occurs in combination with
other error numbers.
Make a note of the numbers of all
errors displayed before this error
and contact VEMAG Customer
Service.
946
External drive 1 manual
The first drive of attachment 2 is
operated manually.
Release manual drive button.
Summary of Contents for HP10E
Page 8: ......
Page 10: ...HP10E HP12E HP15E HP20E Dairy design 0 Foreword 0 2 VEMAG 2013...
Page 26: ...HP10E HP12E HP15E HP20E Dairy design 3 Installation and commissioning 3 6 VEMAG 2013...
Page 34: ...HP10E HP12E HP15E HP20E Dairy design 4 Setting up 4 8 VEMAG 2013...
Page 38: ...HP10E HP12E HP15E HP20E Dairy design 5 Operation 5 4 VEMAG 2013...
Page 52: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 14 VEMAG 2013 Mode group Mode View...
Page 56: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 18 VEMAG 2013...
Page 58: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 20 VEMAG 2013...
Page 60: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 22 VEMAG 2013...
Page 97: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 59 VEMAG 2013...
Page 100: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 62 VEMAG 2013...