6.6.3.6 Speed
Display:
Speed
Unit:
Per cent [%]
Resolution:
0.1 %
Setting range:
0 – 100 %
Application:
All applications (not for pressure control)
• Enter speed.
• Press
Enter
.
Maximum feed rate depends among other things on the feed element and
on the machine type. Speed is limited automatically as a function of filling
weight to ensure accurate portioning. As weight is reduced, maximum
possible speed is adjusted automatically. Only actual speed is reduced
(small grey number in the display).
If the speed is controlled by an attachment (external speed control), you
can enter a minimum and maximum speed. The speed accelerates at a
linear rate between these two values.
Example:
Min. =
is an applied voltage of 0 V
Max. =
is an applied voltage of e.g. 10 V
If the speed is controlled by a hopper level you can enter a minimum, a
normal and maximum value for the speed.
Example:
Min. =
is the speed when the hopper is almost empty
Normal =
is the speed when the hopper is half full
Max. =
is the speed when the hopper is full
Summary of Contents for HP10E
Page 8: ......
Page 10: ...HP10E HP12E HP15E HP20E Dairy design 0 Foreword 0 2 VEMAG 2013...
Page 26: ...HP10E HP12E HP15E HP20E Dairy design 3 Installation and commissioning 3 6 VEMAG 2013...
Page 34: ...HP10E HP12E HP15E HP20E Dairy design 4 Setting up 4 8 VEMAG 2013...
Page 38: ...HP10E HP12E HP15E HP20E Dairy design 5 Operation 5 4 VEMAG 2013...
Page 52: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 14 VEMAG 2013 Mode group Mode View...
Page 56: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 18 VEMAG 2013...
Page 58: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 20 VEMAG 2013...
Page 60: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 22 VEMAG 2013...
Page 97: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 59 VEMAG 2013...
Page 100: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 62 VEMAG 2013...