HP10E / HP12E / HP15E / HP20E - Dairy design
6. Graphical control
6-29
© VEMAG 2013
6.6.3.7 Individual speed
Display:
Individual speed
Unit:
Per cent [%]
Resolution:
0,1 %
Setting range:
25.0 – 75.0 %
Application:
Double outlet
• Enter speed.
• Press
Enter
.
If only one outlet of a double outlet is operated, you can set the speed
for this outlet. The speed percentage for this outlet is displayed in the
„Speed“ parameter (small grey number in the display).
6.6.3.8 Back suction
Display:
Back suction
Selection:
On / Off
Unit:
Gramme [g]
Resolution:
0.1 g
Setting range:
0 – 200 g (0 - 120 g for DP machines)
Application:
When switched on, back suction prevents the product
running on once a portion has ended.
• Enter back suction quantity. Entering "0" switches off the parameter.
• Press
Enter
.
Machines which are not equipped with the standard filling horn holder
but have a larger machine outlet may not perform back suction for safety
reasons. In this case, back suction is blocked. The back suction quantity
may not exceed the specified weight defined in weight (does not apply to
“LPG” mode).
6.6.3.9 LPG belt speed
Display:
LPG belt speed
Unit:
Per cent [%]
Resolution:
1 %
Setting range:
0 – 100 %
Application:
Speed of the dividing belts of the LPG
• Enter belt speed.
• Press
Enter
.
Belt speed can be limited by filling rate and number of links.
Summary of Contents for HP10E
Page 8: ......
Page 10: ...HP10E HP12E HP15E HP20E Dairy design 0 Foreword 0 2 VEMAG 2013...
Page 26: ...HP10E HP12E HP15E HP20E Dairy design 3 Installation and commissioning 3 6 VEMAG 2013...
Page 34: ...HP10E HP12E HP15E HP20E Dairy design 4 Setting up 4 8 VEMAG 2013...
Page 38: ...HP10E HP12E HP15E HP20E Dairy design 5 Operation 5 4 VEMAG 2013...
Page 52: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 14 VEMAG 2013 Mode group Mode View...
Page 56: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 18 VEMAG 2013...
Page 58: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 20 VEMAG 2013...
Page 60: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 22 VEMAG 2013...
Page 97: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 59 VEMAG 2013...
Page 100: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 62 VEMAG 2013...