HP10E / HP12E / HP15E / HP20E - Dairy design
6. Graphical control
6-45
© VEMAG 2013
6.6.4.37 Last hook later
Display:
Last hook later
Unit:
Millisekunden [ms]
Resolution:
1 ms
Setting range:
0 – 999 ms
Application:
AH 204, AH 212
• Enter a delay for the last hook of any stick
• Press
Enter
.
A delay for the last hook is required, for example, to collect a broken-off
portion at the end of a casing section correctly with the hook.