- 36 -
User Manual
Athena
English
• If an operation setting is changed, temperature control will be ON-OFF type until
Tset is reached for the first time; this will help reaching the selected conditions more
quickly.
IMPORTANT: PROPORTIONAL mode selection has no effect on summer operation.
Temperature control is always ON/OFF type in summer operation mode.
ADVANCED PROGRAMMING
• This menu, which is marked by symbol
, sets operation parameters that are
common to all control zones:
°
configuration of individual control zones;
°
existence of an external probe;
°
unit of measurement °C/°F ;
°
bus address of device.
Configuration of individual control zones
• Once in the menu, the page shows the configuration of
the first zone, i.e. Z1.
• To scroll the other zones in a sequence, use key .
• The configuration parameters to be set up for every zone
are:
°
the temperature probe associated to the zone, which
can be:
built-in (INT)
external (EXT)
remote via bus (BUS)
°
the actuator associated to the zone, which can be:
relay (REL)
wireless (RF)
remote via bus (BUS)
°
a description identifying the zone.
NOTE: to remote-program via bus, the
Tx.Athena
radio module must be
installed and the
Athena
programmable thermostat must be placed on the
wall-mounted base.
• If the probe selected for temperature control is an
Athena.Temp
probe, this is when
the probe is configured.
• If the actuator selected for the control zone is a remote actuator
RX4-8A
or
RX1-
8A
, this is when the actuator is configured (either wireless or bus).
ADV