- 40 -
User Manual - CRONO.X programmable thermostat
English
DISPLAY
INITIAL STARTUP – TOTAL RESET
This procedure enables correct operation of the CRONO.X on fi rst startup, or resets
factory settings (Default settings).
Revert to factory settings – TOTAL RESET
• Place 2 alkaline batteries 1.5V – AA size, with correct polarity
• Press : all the segments will appear on the display
• Press
within 3 secs: the reading “
dEF
” will appear
After a few seconds the reading “
12:00
” will fl ash on the display.
• Press
: the minutes will fl ash
• Press
: all the segments will be continuously lit, the hour, minutes and the
temperature measured will appear as well as a set of small squares indicating daily
programming
CRONO.X will operate in automatic mode (cfr. page 42).
• Set the time (cfr. page 41)
Default settings are:
Operation
WINTER-HEATING
Mode
AUTOMATIC
Hourly schedule
MON-FRI PRG1; SAT-SUN PRG2
Temperature T0
5.0°C
Temperature T1
15.0°C
Temperature T2
18.0°C
Day
of the week
Time
Daily
temperature
profi le
System on
– WINTER
-HEATING MODE
System on
– SUMMER
-AIR-CONDITIONING
Timer
on
Internal
temperature
External
temperature
Manual
operation