4. INSTALLATION INSTRUCTIONS
GRIDDLE
GRIDDLE
8. TECHNICAL DATA
A
C
K MBCJ
CG18-2
CG24-4
CG36-6
CG48-8
CG60-5
HEIGHT WITH FOOT in/mm (A)
WIDTH in/mm (B)
18" (457)
24" (609)
36" (914)
48" (1219)
60" (1524)
DEPTH in/mm (C)
WEIGHT lbs/kg
156,9 (71,2) 209.2 (94,9)
284.4 (129)
319,7 (145)
357,1 (162)
BURNERS
2
4
6
8
5
PILOTS
2
4
6
8
5
MAXIMUM POWER NG
30000
60000
90000
120000
150000
MAXIMUM POWER LPG
33332
66664
99996
133328
166660
RCAFLG
A?J B?R?
/ 5ò/ -0 &222'
1/ / -0 &577'
B
18", 24", 36", 48", 60"
(457, 609, 914, 1219, 1524)
4" (101)
21" 1/4 (539)
17" 1/2 (444)
13" 3/8 (340)
31" 1/2 (799)
14" 1/2 (372)
21" 1/8 (536)
8" 1/4 (209)
GAS INLET
Ø3/4 NPT
19" 3/4 (500)
4" 3/8 (1
10)
1" 3/4 (43)
GAS INLET Ø3/4 NPT
The gas pressure regulator provided with the equipment must be installed when the appliance is
connected to the gas supply.
The area around the appliance must be kept free and clear of combustibles such as solvents, cleaning
liquids, brooms, rags, etc.
Proper clearances must be provided at the front of the appliances for servicing and proper operation.
Provisions shall be incorporated in the design of the kitchen, to ensure an adequate supply of fresh
air and adequate clearance for air operanings into the combustion chamber, for proper combustion
and ventilation.
For proper operation of the appliance, do not obstruct the ow of combustion and ventilation air.
The installation must conform with local codes, or in the absence of local codes, with the national fuel
gas code, ANSI Z223.1 - 1988 (or latest addenda).
THIS APPLIANCE IS INTENDED FOR OTHER THAN HOUSE HOLD USE
All Metalúrgica Venâncio commerical gas appliances are manufactured by skilled craftsman using the
finest quality materials.
PROPER installation by qualified personnel is essential for safe, efficient, and trouble-free operation of
the unit. Any alteration and/or tampering, without proper knowledge, tools, and test equipment, is
DANGEROUS and will void all warranties. The installation must conform with local codes, or in the
absence of locel codes, with the National Fuel Gas Code, ANSIZ223.1- latest edition.
PRESSURE TESTING: FAILURE TO INSTALL PRESSURE REGULATOR WILL VOID WARRANTY.
(Most units have a convertible regulator.) The appliance and its indivdual shut-off valve must be
disconnected from the gas supply piping system during any pressure testing of that system at test
pressure in excess of 1/2 psig (3.45 kPa). The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2 psig (3.45 kPa).
NOTICE
The proper installation of this gas appliance is the total responsibility of the end user. It is the
responsibility of the purchaser to determine that the installer is qualified in installation procedures.
Conversion, connecting gas lines, calibrating thermostats, burners, lighters, setting gas pressure with
manometer, and etc., is all part of normal installation and will not be paid for under warranty. If a
warranty technician is called out and finds the unit improperly installed, the end user may be subject
to billing.
FOR MAINTENANCE, SERVICE, REPAIRS, OR INSTALLATION - Contact your dealer or the factory, for
your local Factory Authorized Service Agency.
The gas supply line must be at least 3/4" NPT.