background image

2

 

ENGLISH 

 

INDEX 

SECTION 1:

 Description, guarantee and main characteristics    

 

 

 

   2 

SECTION 2:

 

Safety 

regulations 

         

 

 

SECTION 3:

 Use and maintenance of VV-DC vibrator    

 

 

 

 

   3 

3.0 

Installation 

and 

electrical 

connection 

 

       

 

 

3.1 

Regulating the vibration intensity  

 

 

 

 

 

 

   4 

3.2 

Maintenance 

 

          

 

 

3.3 

Spare 

parts 

 

          

 

 

TABLES:

 Characteristics / drawings / dimensions / spare parts codes.    

 

 

 16 

APPENDIX:

 

CE 

declaration 

of 

conformity 

 

       

19 

 

SECTION 1 - Description, guarantee and main characteristics 

This booklet gives information and all details considered necessary for operators who must install, correctly use and 
service VV-DC vibrators. 
Failure to comply with the regulations described in this handbook may oblige VENANZETTI to void the guarantee 
covering the motor. 
Besides the provisions specified in the supply contract, the Manufacturer guarantees the products for a period of 12 
(twelve) months from the date of purchase. This guarantee solely covers free repair or replacement of those parts 
which, after having been carefully examined by the Manufacturer’s technical department, are recognized as being 
defective. With the exclusion of all responsibility for direct or indirect damages, the guarantee shall only cover material 
defects and shall cease to be of effect should the parts have been disassembled, tampered with or repaired by third 
parties. 
Damages caused by negligence, carelessness, bad and improper use of the motor- driven vibrator, incorrect 
manoeuvres or incorrect installation shall also be excluded from the guarantee. 
Removal of the safety devices with which the motor vibrator has been equipped shall automatically void the guarantee 
and the Manufacturer’s liabilities. This guarantee also becomes void when non-original spare parts have been used. 
Even when under guarantee, returned equipment shall be dispatched to us Carriage Paid. 
VV-DC vibrators are manufactured following the European Community Directives. The basic technical characteristics 
are: 

insulation 

class 

F; 

    - 

mechanical 

protection 

IP66; 

12V or 24V direct current power apply; 

 

 

- impact protection IK08 

operating ambient temperature: -20°C ÷ +40°C; 

maintenance 

free; 

    - 

continuous 

duty. 

 

SECTION 2 - Safety regulations 

Users are advised to become fully familiar with the instructions in this booklet, particularly the safety regulations, paying 
great attention to those operations that are particularly dangerous. 
The Manufacturer declines all and every responsibility for failure to comply with the safetyandaccident-
preventingprovisionsdescribedherein.TheManufactureralso declines all responsibility for damage caused by improper 
use of the motor. 

 

Pay attention to the danger signs in this booklet. They precede an indication of a potential danger. 
When electrically operated equipment is used, it is necessary to take all the necessary precautions in order to 
reduce the risk of fire outbreak, electric shocks and personal injuries. Before the motor-vibrator is used 
carefully read and become fully familiar with the following safety regulations. Keep this booklet in a safe place 
after it has been read. 

It is strictly forbidden to use the motor-vibrator in satured environments with explosion risk. 

 

 

Summary of Contents for V204699

Page 1: ...Sede legale Via dell Annunciata 21 20121 Milano Italy www venanzettivibrazioni it Serie VV DC DC Electric Vibrators Motovibrateurs Gleichstrom Vibrationsmotoren GB OPERATION MANUAL FR GUIDE TECNIQUE...

Page 2: ...e excluded from the guarantee Removal of the safety devices with which the motor vibrator has been equipped shall automatically void the guarantee and the Manufacturer s liabilities This guarantee als...

Page 3: ...at the shaft is free to turn VENANZETTI vibrators can be installed in any position The vibrator must be rigidly fixed to a perfectly flat structure 0 25mm with bolts and nuts type 8 8 Use a torque wre...

Page 4: ...g that the seals n 6 page 16 are on good conditions and have correctly fitted into their housings 3 2 MAINTENANCE The vibrators need no particular maintenance Before servicing a vibrator wait until th...

Page 5: ...ed servicing will now all be accessible remove the old brushes n 11 from their housing and unscrew the relative cable Now fit the new brushes in the correct position make the electrical connections an...

Page 6: ...ropre du motovibrateur aux manoeuvres erron es et une installation inadapt e La garantie ainsi que la responsabilit du Constructeur cessent imm diatement si les dispositifs de s curit dont le motovibr...

Page 7: ...asses et v rifier que l arbre tourne librement Les motovibrateurs VENANZETTI peuvent tre install s dans n importe quelle position Le motovibrateur doit tre fix une structure parfaitement plate 0 25mm...

Page 8: ...arbre n 4 page 16 Tourner les masses r glables des deux c t s n 7 page 16 jusqu obtenir le r glage d sir que l on peut lire sur le disque gradu n 9 page 16 comme pourcentage de force centrifuge maxim...

Page 9: ...une orthogonalit parfaite entre la bride et la carcasse m me quand on enl ve la premi re bride pour ne pas endommager les roulements n 13 D s lors les pi ces sur lesquelles peut tre fait l entretien s...

Page 10: ...ebrochen oder repariert worden sind Nicht unter Garantie fallen au erdem alle Sch den die durch Nachl ssigkeit mangelnde Pflege unsachgem e Benutzung und nicht bestimmungsm igen Einsatz des Unwuchtmot...

Page 11: ...tlich nicht fit ist den Unwuchtmotor anfassen oder benutzen Sicherstellen dass die Stromversorgungsanlage normengerecht ist Die Unversehrtheit des Kabels muss in regelm igen Abst nden gepr ft werden W...

Page 12: ...nd wieder neu starten Kontrollieren dass der entnommene Strom nicht den Wert auf dem Schild berschreitet Andernfalls Pr fen dass das elastische System und die Metallteile mit den blichen Anforderungen...

Page 13: ...der Durchmesser des Lagersitzes ist auf der einen Seite gr sser als auf der anderen Seite In den gr eren Sitz muss das Lager eingepresst werden radial der andere Sitz ist frei Pressen Sie nun das zwe...

Page 14: ...enken Um die Lager zu ersetzen sind sie aus ihrer Aufnahme zu dr cken um dann den Zustand der Lageraufnahme zu pr fen Wenn dieser nicht besch digt ist ein neues Lagereinsetzen Sonst ist der gesamte Fl...

Page 15: ...15...

Page 16: ...0508670 0508670 7 0517747 0517751 9 0517746 0517750 13 0507029 0507029 15 M6x18 M6x18 17 25 27 4x4X6 4x4x6 28 30 0537047 0537047 44 0514017 0514017 54 0500011 0500011 55 M4x6 M4x6 56 4 DIN6798A 4 DIN6...

Page 17: ...03N 2 3000 2 4 120 1 19 100 8 0 4 0 2 0 6 0 V204799 VV DC 05N 2 3000 4 2 211 2 07 190 8 0 4 0 2 0 7 0 CLAMPING TORQUES COUPLES DE SERRAGE ANZUGSMOMENTE ft lbs kg m M4 2 2 0 3 M5 4 4 0 6 M6 7 2 1 0 M8...

Page 18: ...85 1 20 122 93 9 60 19923 43695 100 000 x M8 5 16 M10 3 8 M12 1 2 2 30 16 5 4 80 35 0 8 00 58 0 VV DC 05N 2 100 77 50 4 04 3 10 2 02 203 2 156 5 101 6 4312 9438 34494 x M8 5 16 M10 3 8 M12 1 2 2 30 16...

Page 19: ...19...

Reviews: