Operating

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Power switch 

Power switch PWR On the left side of the panel, press PWR to power on, press PWR 

again to turn off. 

 

Band and Frequency selection 

 

Short press the right VFO knob of the panel to select between 40 meters and 20 meters. 

Rotate VFO knob to change the stored working frequency. The storage frequency of each 

band is from MEM-01 to MEM-05. If you press this knob for more than 2 seconds, it 

will enter the VFO function, and you can change the frequency of the stored frequency. 

When the desired frequency is turned, you can press the knob again for 2 seconds. SAV 

will be displayed on the screen, and this new frequency will be stored in the 

corresponding memory frequency and exit the VFO function. A short press of this knob 

will not save the new frequency and exit the VFO function. 

 

 

Transmitting (VOX)

 

 

Transmit is by the input audio signals from DATA IN,when the input singals are 

greater than the trigger level,it is automatically switched to transmit.The red LCD 
marked TX in the upper left corner of the panel is illuminated when transmitting,its 
brightness indicates the output power level,and RX in the lower right corner of the 
LCD becomes TX.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

Reviews: