7.  HANDLING & STORAGE 

The fans are delivered on wooden pallets wrapped in plastic stretch. Transport the fan to the place of 

assembly in its original packaging. During transport, connection cables, terminal box and wire connections 
mustn’t be damaged. Load and unload the fan carefully, in order to avoid possible damage. Use suitable 
lifting equipment. The fan should be stored in a safe, clean, dry, vibration free, location. A regular monthly 
rapid spin of the impeller is recommended to prevent grease hardening and possible brinelling of the 
bearings; the impeller should not be in the same angular position after rotation. 

When dismantling the crate to gain access to the fan assembly care should be taken to avoid injury from 

sharp edges, nails, staples, splinters, etc. 

8.  MAINTENANCE 

 

Periodically check the screw connections, coil resistance, function of the safety components and control 

elements. Only clean the fan manually, with a vacuum cleaner or with compressed air. Before service, 
maintenance or repairing, disconnect the electrical connections and the impeller is stopped. The fan must be 
cleaned when needed, at least once per year to maintain the capacity. The fan bearings are maintenance-
free and should be renewed only when necessary. Cleaning should be done without dislodging or damaging 
the impeller. Make sure that there is no unexpected noise from the fan. 

In addition to routine maintenance motor bearings will in the longer term require attention. If the motor 

bearings are greased through extended lubricators, a quality of grease should be periodically applied in 
accordance with the information on the fan or motor nameplate and/or instructions provided. 

9.  FAULT DETECTION 

It is necessary to turn off the fan before checking the fan and the system. During maintenance, device 

electrical connections should be cut entirely. All switches and circuit breakers should be locked by brought to 
the OFF position. Also “DO NOT START” sign should be placed on the control panel that will consistently 
stand. 

Check that the electrical connections to the unit are secure. Check that the voltage applied at the fan 

terminals is as specified on the motor nameplate, and is balanced. Measure the current on each phase (one 
phase in the case of single-phase motors) of the motor in turn and check that the current consumption is 
within the full load current specified on the motor nameplate. 

Rotate the motor shaft by hand. Investigate any sound of grinding noises, internal chaffing, rubbing or 

stiffness. Any observed defect may indicate that the bearings require lubrication or replacement. Ensure that 
all fixings are secure. Make sure that the fan blade is not blocked by an object, if fan is still not working, 
contact your supplier.  

 

 

10. WARRANTY 

The warranty period starts from the date of delivery and it is for 2 years. Including all parts of the 

entire fan under warranty. The maximum repairing period is 30 business days. This period starts from 
the date of notification to us. Fan's warranty does not include electrical connection errors, failures that 
may arise due to voltage and user errors. The warranty is only valid under condition that the fan is 
assembled, operated and periodic maintenance to be made according to this manual.  

 

ALWAYS  WEAR  APPROPRIATE  PROTECTIVE  CLOTHING  (INCLUDING  HARD 
HATS,  EYE  PROTECTORS  A

ND  EAR  DEFENDERS)  WHEN  WORKİNG  IN  THE 

VICINITY OF THE FAN ASSEMBLY 