3.  TECHNICAL SPECIFICATION for HEAT RECOVERY UNITS  

Technical  specifications,  which  are  valid  for  the  heat  pump  heat  recovery  units  are  given  in  the  table 
below.  

  

Table 3.1. VHR DX Heat Pump Heat Recovery Unit Technical Specifications  

MODEL 

VHR 05 

DX 

VHR 07 

DX  

VHR 10 

DX  

VHR 15 

DX  

VHR 20 

DX  

VHR 21 

DX  

VHR 30 

DX  

VHR 40 

DX  

Air Flow 

m³/h 

500 

750 

1000 

1500 

2000 

2000 

3000 

4000 

External Static Pressure(0 

Pa) 

Pa 

165 

188 

223 

226 

181 

262 

168 

300 

EL

ECTRICAL 

DATA

 

Electrical Data 

 

230Volt / 50Hz 

400 Volt / 50 Hz 

Fan Absorbed Power 

2x102 

2x155 

2x225 

2x515 

2x515 

2x550 

2x550 

2x1400 

Coo

lin

g

 

Compressor 

Absorbed Power 

1050 

1050 

1400 

2250 

2800 

2800 

3410 

4640 

Total Absorbed 

Power  

1254 

1360 

1850 

3270 

3820 

3820 

4430 

7040 

Total Cooling 

Capacity 

3488 

3751 

4615 

7460 

9552 

9552 

13430 

18460 

Btu/h 

11900 

12800 

15750 

26070 

32600 

32600 

45833 

63000 

Hea

ti

n

g

 

Compressor 

Absorbed Power 

686 

541 

805 

1362 

1456 

1456 

2740 

3370 

Total Absorbed 

Power 

890 

841 

1425 

2382 

2476 

2476 

3760 

5570 

Total Heating 

Capacity 

5660 

6760 

8660 

13910 

17930 

17930 

24350 

32240 

Btu/h 

19300 

23050 

29550 

47450 

61180 

61180 

83080 

110000 

Air Filter 

 

Placed at  fresh and exhaust air inlet - Cassette Filter 

 

 

 

 

 

 

 

Summary of Contents for VHR 05 DX

Page 1: ...NANCE INSTRUCTION HEAT PUMP HEAT RECOVERY UNITS VHR MODELS VENCO Havaland rma ve Makina San ve Tic A 2004 Cad No 5 45400 OSB Turgutlu MANISA TURKEY Tel 0 236 332 5070 Fax 0 236 332 5030 www venco com...

Page 2: ...rage 7 5 3 Installation 8 Figure 5 3 1 Connection Schema 8 Figure 5 3 2 Installation Schema 8 Figure 5 3 3 Installation Schema 9 6 CONNECTIONS 10 6 1 Duct Connections 10 Figure 6 1 1 In Free Outlet 10...

Page 3: ...nicians 16 9 4 General Hazards Prevention 16 Table 9 4 1 General Hazards 16 10 START UP AND OPERATING 17 10 1 Commissioning 17 10 2 Operating 17 11 ELECTRONIC CONTROLLER BOARD 19 11 1 DX Controller 19...

Page 4: ...Y UNITS and VHR MODELS VENCO Heat Recovery Units are classified 8 different models VHR 05 DX 07 DX 10 DX 15 DX 20 DX 21 DX 30 DX 40 DX Figure 2 1 In all models the housing is made from epoxy coated ga...

Page 5: ...controller Fresh air fan stop running 30 seconds after to cool the electrical heater when the unit switch off DX controller has a protection system optional against the frost formation at the temperat...

Page 6: ...Volt 50Hz 400 Volt 50 Hz Fan Absorbed Power W 2x102 2x155 2x225 2x515 2x515 2x550 2x550 2x1400 Cooling Compressor Absorbed Power W 1050 1050 1400 2250 2800 2800 3410 4640 Total Absorbed Power W 1254 1...

Page 7: ...1375 1525 1650 1650 Height mm H 390 440 440 460 610 610 735 735 Duct Connection mm d 200 200 250 300 355 355 400 450 Weight kg 89 112 165 263 300 325 420 520 Dimensions mm W1 180 180 225 300 300 320...

Page 8: ...landing heat recovery units are damaged especially due to wrong methods usage Appropriate lifting methods should be used in order to minimize any possible damage Trans pallet or forklift can be used f...

Page 9: ...ill cause a problem There should be sufficient amount of place around the unit to be able to give service and for piping connections Heat recovery units should be assembled onto a hard and flat base D...

Page 10: ...2016 09 9 28 Figure 5 3 3 Installation Schema Fan service cover Model 1 Filter service cover Fan service cover Model 2 Filter service cover...

Page 11: ...portant when the applications for orifice and distributor which use laminar method for pressure calculation Turbulence causes increasing the pressure loses Figure 6 1 1 Figure 6 1 1 In Free Outlet It...

Page 12: ...described left side 6 3 Electrical Connections The electrical materials cables and all relevant control and remote control equipment should be chosen and designed suitable to unit requirements All th...

Page 13: ...n possible dangers and precautions Never expose the unit to moisture strokes and external effects Don t use your products in explosive and corrosive conditions The unit should be maintained by trained...

Page 14: ...START UP Please make sure that all electricity cables are made according to EN 60204 1 standards and security and protection units belong to all elements Please make sure that all parts of the unit ar...

Page 15: ...owever it is advised to change synthetic filters every two years 8 3 Heat Recovery Exchanger Is controlled before transportation The plates of heat recovery exchanger should be checked after transport...

Page 16: ...Heat Recovery Ventilation units as well as providing energy savings has been designed to achieve a high quality of indoor air Use for other purposes is deemed as illegal In such cases the user will b...

Page 17: ...utting Into Operation Maintenance For the continuity of the warranty control and maintenance responsibilities have to be accepted and followed strictly You can apply to VENCO A S to train your authori...

Page 18: ...carefully After switching on the unit the sound should be listened Motor current values should be checked with label values whether it is appropriate 10 2 Operating After maintenance and service manu...

Page 19: ...or questions about the changes during periodic observations you can contact VENCO or other competent adviser Make the fan stop until to fix if any vibration appears at fan The changes of sound level a...

Page 20: ...on the control keys are given in the following template Figure 11 1 1 DX Controller Table 11 1 1 DX Key Pads Controls Button Name Description ON OFF Unit will be ON or OFF MODE Select Running Status C...

Page 21: ...ller can perform device ON OFF from the dry contact information it gets from the building automation system or similar system VRV VRF controller timer etc By a dry contact on the relay card connected...

Page 22: ...lure by an authorized service 13 COMMISSIONING AND START UP Turn off the fan before check the fan and system During maintenance the electrical connection of the unit should be stopped completely All s...

Page 23: ...2016 09 22 28...

Page 24: ...not closed or duct connections are not completed Check the doors and duct connections HIGH AIR FLOW Duct resistance is very low than expected Check and compare the external static pressure according t...

Page 25: ...ontrol and cleaning done by the user Users must contact with VENCO for the faults They identify during the maintenance or commissioning operation Contact the information s given below for your service...

Page 26: ...2016 09 25 28 15 APPENDIX 15 1 DHR DX 3 0 Electrical Wiring Diagram 5 7 10 15 20 21 30 DX...

Page 27: ...2016 09 26 28 15 2 DHR DX 3 0 Electrical Wiring Diagram 40 DX...

Page 28: ...2016 09 27 28 15 3 DHR DX 3 1 PRO Electrical Wiring Diagram 40 DX...

Page 29: ...olt 50 Hz 20A VHR 20 DX 3820W 230 volt 50 Hz 25A VHR 21 DX 3820W 230 volt 50 Hz 25A VHR 30 DX 5986W 400 volt 50 Hz 3X16A VHR 40 DX 8400W 400 volt 50 Hz 3X16A Wiring MODEL Cable section mm 1 5 2 5 4 6...

Reviews: