8
For instance, if during a vend the controller
detected a motor switch failure, that selection
would be flagged as faulty and would be
disabled. That motor would display the next time
the
Service Mode
is entered.
MDB Errors
NOTE
The following errors are only displayed
when the
Service Mode
is entered. Record
the displayed information immediately upon
entering the
Service Mode
. Any keypad
input or exiting of the
Service Mode
will
erase the MDB error codes.
Table 1. Error Codes
DISPLAYS
INDICATES
CScF
Invalid mechanism scale factor
tSnS
Defective coin tube mechanism
CJAM
Coin jam detected
tJAM
Coin tube jam detected
CnEr
Coin acceptance problem detected
AcEr
Acceptor unplugged
ChEr
Coin mechanism ROM checksum bad
bScF
Invalid acceptor scale factor
bSnS
Defective bill sensor
bJAM
Bill jam detected
StFL
Bill stacker is full
CShb
Bill cash box is out of position
bMtr
Bad bill motor detected
bLEr
Bill acceptor ROM checksum bad
rScF
Invalid card reader scale factor
CdEr
Card error detected
bCrd
Invalid card detected
rJAM
Card reader jam detected
CoEr
Communications error detected
brdr
Card reader failure
Programming the Controller
To access the programming, enter the
Service
Mode,
then choose from the following modes.
Table 2. Modes
PRESS
DISPLAYS
MODE
[ 1 ]
Coin
Coin Dispense
[ 2 ]
Motor Count
[ 3 ]
Acct
Accountability
[ 4 ]
Prc
Price Setting
[ 5 ]
Slct
Test Vend Single Motor
[ 6 ]
Test Vend All Motors
[ E ]
Optn
Vend Options
[ B ]
ºDeg
(temperature)
Refrigeration Control
(not used on this machine)
Coin Dispense Mode
In the Coin Dispense Mode, coins stored in the
coin mechanism payout tubes can be removed.
Press the Service Mode Button, then press
[
1 ]
.
Coin
displays. See Table 3.
Table 3. Coin Dispense Keys
PRESS
TO DISPENSE A COIN OF:
[ A ]
the lowest denomination
[ B ]
the next higher denomination
[ C ]
the next higher denomination
[ D ]
the highest denomination
Pressing a key once will pay out one coin.
Pushing and holding a key will allow the coins to
pay out at a rate of approximately two per
second. Coins will continue to be dispensed from
the payout tube as long as its activating key is
pressed.
Pushing any key other than
[ A ]
,
[ B ]
,
[ C ]
or
[ D ]
will exit back into the
Service Mode
.
Summary of Contents for 3120-GF12 II
Page 18: ...16 SCHEMATIC GF12 II P N 4209903...