background image

Installation and User Manual

PRO225 & PRO250

H

EAT

R

ECOVERY

V

ENTILATORS

READ AND SAVE THESE INSTRUCTIONS

Venmar Ventilation inc., 550 Lemire Blvd., Drummondville, QC, Canada J2C 7W9

www.venmar.ca

VB0121

These products earned the 
ENERGY STAR

®

by meeting strict

energy efficiency guidelines set by
Natural Resources Canada and the
US EPA. They meet ENERGY STAR
requirements only when used 
in Canada.

08305 rev. C

Summary of Contents for PRO225

Page 1: ...NS Venmar Ventilation inc 550 Lemire Blvd Drummondville QC Canada J2C 7W9 www venmar ca VB0121 These products earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resou...

Page 2: ...extension cord 9 Do not install in a cooking area or connect directly to any appliances 10 Do not use to exhaust hazardous or explosive materials and vapors 11 Do not run any air ducts directly above...

Page 3: ...ANCE 19 7 1 Regular Maintenance 19 7 2 Annual Maintenance 19 8 TROUBLESHOOTING 20 TABLE OF CONTENTS Congratulations You have made an excellent choice The operating principle of your Heat Recovery Vent...

Page 4: ...out the following operations During winter these units recover the heat contained in the stale air before it is exhausted and transfer it to the fresh air drawn from the outside reverse process in su...

Page 5: ...diagrams Please note that the stale air never mixes with the fresh air DURING AIR EXCHANGE VF0045 FRESH AIR FROM OUTSIDE FRESH AIR TO BUILDING STALE AIR FROM BUILDING STALE AIR TO OUTSIDE DURING DEFRO...

Page 6: ...side temperature 5 C 23 F to 27 C 17 F or coldest and will increase in frequency as the temperature decreases Its duration is of 7 or 10 minutes 8 Adjusting tools 2 adjust the dampers one on each side...

Page 7: ...NTRAL STAIRWAY CLOSED IN BASEMENT STAIRWELL 2 STORIED HOUSE CENTRAL STAIRWAY CLOSED IN BASEMENT STAIRWELL Basement installation kit no CH30115 Basement installation kit no CH30115 with one additional...

Page 8: ...in is close by use a pail to collect run off Away from hot chimneys electrical panel and other fire hazards Allow for a power source standard 3 prong grounding outlet Use the 4 chains and springs from...

Page 9: ...he stairway as possible and in such a way that the air circulates in all the lived in spaces in the house If a register is installed in the kitchen it must be located at least 4 feet 1 2 m from the ra...

Page 10: ...ase refer to your local building code 0 METAL TRANSITION B FRESH AIR TO BUILDING DUCT AND EXHAUST AIR FROM BUILDING DUCTS Fresh air to building duct See point A above Fresh air to building duct only E...

Page 11: ...resh air to building Distribution d air frais 1 Use the following procedure for connecting the insulated flexible ducts to the unit ports exhaust to outside and fresh air from outside a Pull back the...

Page 12: ...LE AIR EXHAUST PORT FRESH AIR INTAKE PORT 6 1 8 M 6 1 8 M 18 457 MM 18 457 MM 6 152 MM 18 457 MM OPTIONAL LOCATION 4 9 CONNECTING INSULATED DUCTS TO EXTERIOR PORTS For each exterior port using a jig s...

Page 13: ...CONNECTING THE DRAIN Make a water trap loop in the tube to prevent the unit from drawing unpleasant odors from the drain source Make sure this loop is located OVER the T as shown Run the tube to the f...

Page 14: ...onic module inside the unit 0 BOOT SEQUENCE The unit boot sequence is similar to a personal computer boot sequence Each times the unit is plugged after being unplugged or after a power failure the uni...

Page 15: ...NAL CONNECTOR 5 2 3 20 MINUTE LIGHTED PUSH BUTTON OPTIONAL AUXILIARY CONTROL PRO250 PRO 225 NO C NC I OC OL Y R G B VE0185 ON 5 2 CONTROLS CONNECTION TO THE UNIT CONT D 5 2 2 11136 MAIN CONTROL PRO225...

Page 16: ...an also be controlled using the included main controls the Breeze main control for the PRO250 unit and the 11136 main control for the PRO225 unit WARNING Always disconnect the unit before making any c...

Page 17: ...ill turn OFF for the first 40 minutes and operate on air exchange mode with the outside in low speed during the last 20 minutes of the hour The air exchange indicator will be lit If the humidity contr...

Page 18: ...or the present humidity level precision of 5 Turn the selector to the right of the click to lower the humidity level in the house This will initiate the air exchange mode on your ventilation system an...

Page 19: ...necessary Also check during very cold weather because ice may grow on the screen located at the exterior intake hood WARNING Dangerous voltage may be present During maintenance and repairs the unit mu...

Page 20: ...unit is receiving power from the house circuit breaker or fuse 6 Condensation on windows Air too humid Adjust the humidity control knob as per instructions see Section 6 Leave curtains half open to a...

Page 21: ...be used in a building as defined below Building All structures zoned and or erected for the act process or art of human or animal habitation and or the storage or warehousing of goods Residential use...

Page 22: ...22 This page is left empty...

Page 23: ...stionnaire within 10 days of your purchase to the address below Note that only the questions on this side of the page are mandatory Your answers will be used for market research studies and reports an...

Page 24: ...e probl mes sp ci ques Autres Pr cisez SVP Qui a install l appareil Constructeur de la maison Installateur recommand Ami membre de la famille Entrepreneur Vous m me Veuillez lire la liste des crit res...

Reviews: