background image

Connection - LED codes

The LED will flash red a 
number of times based
on the model of the 
thermostat it recognizes.

  1 flash     = T2700
  2 flashes = T2800
  3 flashes = T2900
  4 flashes = T1700
  5 flashes = T1800
  6 flashes = T1900
 

The LED will turn green when
the programmer is ready to 
continue.

The LED will turn red during
operation and back to green
when finished.

After the accessory connector 
of the programmer is inserted 
into the accessory jack of a 
compatible thermostat:

Red/Green LED

CAUTION

Do not remove the Ez Programmer from the
thermostat while the LED is red.  

If the LED 

 

red longer than 3 seconds, remove it from the 
thermostat as this is an abnormal condition.  
In this case let the programmer sit 5 seconds, 
then reconnect and retry the previous operation.

is 

Reconnect, if the red/green
LED does not flash at all.

Page 5

COMMERCIAL PROGRAMMABLE THERMOSTAT

HUMIDITY

FAN 

PROGRAM HOLIDAY

MODE

OVERRIDE

OUTDOOR

SET CLOCK

PLATINUM

eries

AUTO

I2:00

Su

Pm

H

EAT

C

OOL

72

74

Summary of Contents for ACC0432

Page 1: ...or a complete list OWNER S MANUAL OWNER S MANUAL Allows quick and easy copying from one thermostat to the next Choose from clock time period programming or all data copy Battery backup keeps the clock and day of the week current Stores data from several models simultaneously EZ EZ Thermostat Thermostat Programmer Programmer ...

Page 2: ... manually enter each item With the EZ Programmer your options are Copy all data from a thermostat time day of week time period programming and advanced setup information Load just the time and day of week to a thermostat Load just the time period programming to a thermostat Load all data to a thermostat time day of week time period programming and advanced setup information ...

Page 3: ... location An easy way to change the time on multiple units The EZ Programmer has a unique location in its memory to store data from each thermostat model that it is compatible with The EZ Programmer will automatically recognize the thermostat model that it is connected to and upload the correct data for that model The EZ Programmer over writes only the existing data for the model being downloaded ...

Page 4: ...tat bottom Accessory release button Accessory connector The LED will glow green when connected to a compatible thermostat To release the programmer from the thermostat press and hold the accessory release button on the front panel of the thermostat while pressing the release button remove the programmer The accessory connector of the programmer is inserted into the accessory jack Page 4 ...

Page 5: ...f the programmer is inserted into the accessory jack of a compatible thermostat Red Green LED CAUTION Do not remove the Ez Programmer from the thermostat while the LED is red If the LED red longer than 3 seconds remove it from the thermostat as this is an abnormal condition In this case let the programmer sit 5 seconds then reconnect and retry the previous operation is Reconnect if the red green L...

Page 6: ... from the programmer to the connected thermostat The LED will turn red then will turn green when complete will This button when pressed copy download all the stored data from the connected thermostat to the programmer The LED will turn red then will turn green when complete will This button when pressed copy upload all the stored data from the programmer to the connected thermostat The LED will tu...

Page 7: ...l turn red then turn green when copying is complete will Operation Copy All Data To download All data To upload All data programming This button when pressed will copy upload all the stored data from the programmer to the connected thermostat The LED of the programmer will turn red then turn green when copying is complete ALL ALL Page 7 ...

Page 8: ... PERIOD To upload Time Period programming This button when pressed will copy upload all the time period data from the programmer to the connected thermostat The LED of the programmer will turn red then turn green when copying is complete Page 8 ...

Page 9: ...ay of the week from the programmer to the connected thermostat The LED of the programmer will turn red then turn green when copying is complete Note If connected to a thermostat that does not have a clock the programmer will not try to transfer the clock information In this case the LED will not flash red Page 9 ...

Page 10: ... will need to be reset after replacing the battery To do this connect the programmer to a compatible thermostat with a clock and day of the week display Confirm the current day and time then press To completely the contents of the programmer and restore it to its factory default values insert a paperclip into this hole and depress the small reset switch erase all of ALL Screw holding the battery c...

Page 11: ...info Vacation w set points Holiday w set points Occupied set points Unocc set points Preoccupancy purge 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 ...

Page 12: ...NDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the installation and servicing instructions or owner s manual including filter cleaning and or replacement a...