40
Sample Wiring Diagrams
Heat Pump Systems with Dual Fuel
Humidification or Dehumidification
G
Y1
Y2
W3
R
W1/O/B
W2
HUM
DEHUM
C
AUX
REMOTE
SENSOR
DRY
CONTACT
OUTDOOR
SENSOR
Humidification
System
DEHUM/
HUM
Dehumidification Terminal
on Equipment
Dry Contact and Aux Output
G
Y1
Y2
W3
R
W1/O/B
W2
HUM
DEHUM
C
AUX
REMOTE
SENSOR
DRY
CONTACT
OUTDOOR
SENSOR
Residential & Commercial
Heat Pump
with
O Reversing Valve
5 Wire, 1 Stage Cooling, 1 Stage Heat
R 24VAC Power
C 24VAC Common
W1/O/B Reversing Valve
Y1 1st Stage Compressor
(Cool or Heat)
G Fan
Residential & Commercial
Heat Pump
with
O Reversing Valve.
8 Wire, 2 Stage Cooling, 4 Stage Heat
R 24VAC Power
C 24VAC Common
W1/O/B Reversing Valve
W2 3rd Stage Heat
W3 4th Stage Heat
Y1 1st Stage Compressor
(Cool or Heat)
Y2 2nd Stage Compressor
(Cool or Heat)
G Fan
Setup Step 31 is set to 2
(Number of Compressor Stages)
Residential & Commercial
Heat Pump
with
O Reversing Valve
6 Wire, 1 Stage Cooling, 2 Stage Heat
R 24VAC Power
C 24VAC Common
W1/O/B Reversing Valve
Y1 1st Stage Compressor
(Cool or Heat)
W2 Aux Heat
G Fan
Residential & Commercial
Heat Pump
with
O Reversing Valve.
7 Wire, 2 Stage Cooling, 3 Stage Heat
R 24VAC Power
C 24VAC Common
W1/O/B Reversing Valve
W2 3rd Stage Heat
Y1 1st Stage Compressor
(Cool or Heat)
Y2 2nd Stage Compressor
(Cool or Heat)
G Fan
Setup Step 24 is set to 2
(Number of Compressor Stages)
1
GAS
O
GAS/EL
ELEC
B
HP
ON
23
1
GAS
O
GAS/EL
ELEC
B
HP
ON
23
1
GAS
O
GAS/EL
ELEC
B
HP
ON
23
1
GAS
O
GAS/EL
ELEC
B
HP
ON
23
24V is present between these two
terminals whenever the air quality is at/
worse than the specified limit. Use a relay
to interface to external devices for helping
improve air quality (fresh air dampers,
exhaust fans, electronic air cleaners, etc)
Accessory such as a
condensate overflow switch
or occupancy sensor
Installation Instructions