Sample Wiring Diagrams
Heat Pump
CK1
GND
RS
RS+5
W2
Y2
C
G
Y1
W1-O-B
R
POWER
R
COMPRESSOR
Y
O
/b
REVERSING VALVE**
COMMON
C
FAN
G
6 Wire, 1 Stage Cooling, 2 Stage Heat-Heat Pump* with O or b reversing valve**.
Residential Heat Pumps, split systems & package units, with auxiliary heat.
2nd STAGE
HEATING
W
2
*
This option must be selected ON during advanced setup
(see page 12, step 3 of Owner’s Manual).
**
This option must be selected O or b during advanced setup
(see page 13, step 4 of Owner’s Manual).
Page 11