If you wish to change the house code from the factory preset of zero, follow 
the instructions on page 12 of the Wireless Thermostat Owner’s Manual to 
enter Advanced Setup.

Comm LED illuminated
if  Comm  is  good  and 
thermostat’s backlight
is on.

When  the  Wireless  Thermostat  has  good  communication 
with the RF Module, and the wired thermostat’s backlight 
has  been programmed to be on continuously,  the  LED  of 
the RF Module will be illuminated.

FAN

MODE

  HC

0

4

Setup

Match the T1100RF house 
code  to  the  RF  Module’s 
dip switches using the UP 
and DOWN arrow keys.

C

c

F

Add-A-Wireless

Thermostat

T1119RF

 FCC ID MUH-T10013

Using the UP and DOWN arrow keys, program the house code you have 
selected for the RF Module into the Wireless Thermostat.

In advanced setup, press the MODE button to advance to setup step #4
on page 13 in the Owner’s Manual.

Separate the wireless thermostat from its backplate by 
pulling the top of the backplate with one hand while 
pulling on the top corner of the thermostat your other 
hand.

Now turn the wireless thermostat over 
and place the AA Lithium batteries 
into the battery holder.  

Note:  After installing the batt-
eries,  two  dashes  will  appear 
momentarily.  

Snap  the  backplate  back 
onto the thermostat once 
the  batteries  have  been 
installed.

MODEL:  T1100RF

T070500138

T1

Y2

Q4

2
.

0
1

AA Lithium

   Battery

AA

 L

ith

iu

m

   

Ba

tte

ry

Troubleshooting Tip #1:  If the thermostat’s backlight is on continuously, but the Comm LED on the RF 
Module  is  not  continuously  illuminated,  bring  the  T1100RF  Thermostat  within  five  feet  of  the  RF 
Module.    If  the  Comm  LED  still  does  not  illuminate  try  adjusting  the  house  code  setting  or  check 
batteries of the T1100RF thermostat.

Troubleshooting Tip #2:  If the RF Module has been connected to a T1800 or T1900 thermostat that 
is not compatible, the Comm LED will blink rapidly to indicate this error.