30
ADR*
(Setup Step 58)
Controls whether you want the thermostat to possibly respond to signals from the utility
provider. Select ON to allow this and to have steps 59-65 appear. For these steps to
have effect, your utility provider must have an applicable program in your service area
in which Skyport participates and your thermostat is enrolled in the program. Check
with your provider for enrollment details.
ADR Action*
(Setup Step 59)
Observe Setpoint Offsets –
will offset the heat and cool setpoints by the amounts
specified in setup steps 64 and 65.
Observe Static Setpoints –
will set the heat and cool setpoints to the values specified
in setup steps 62 and 63.
Press the SETUP button, then press MODE repeatedly until the
desired setup step appears. Use the WARMER or COOLER buttons
to make selection. Press MODE to advance to the next step.
Press/hold MODE to go backwards to prior steps. Press SETUP to
leave the setup screens.
WARMER
COOLER
MODE
SETUP
Setup Steps
DISPLAY INDICATIONS WHEN AN ADR EVENT IS HAPPENING
After setting your desired values for use during an ADR event, the scrolling display will
give a little information when an event is pending or active. For instance, when an ADR
event has been sent to your thermostat, you might see ADR STARTS at 4:15 to notify
you of a pending event. Once active, you might see ADR STOPS at 5:30.If you have
configured a threshold for cost of energy past which you want to trigger an event, you
will see PRICING EVENT on the display. When an event is active, you can press any of
COOLER, WARMER or MODE buttons, followed by the WARMER to opt out of the event.