24
User Setup -
Service Filter
These setup steps allow the user to monitor equipment runtimes and program
service alerts. Service alerts are displayed in the scrolling marquee.
Runtime hours or days
appear in the clock display.
Press and hold FAN to clear
service alert messages from
the scrolling marquee.
Press the SETUP button, then press MODE repeatedly until the desired setup
step appears. Use the WARMER or COOLER buttons to make selection. Press
MODE to advance to the next step. Press SETUP to leave the setup screens.
Service Filter Runtime
(setup steps 9-10, 17-18)
Current Service Filter Runtime Hours (Setup Step 9) - This counter keeps track
of the number of hours of fan runtime in the Heating mode, Cooling mode,
and in stand alone Fan operation. Press FAN to reset.
Current Service Filter Calendar Days (Setup Step 10) - This counter displays
the total number of calendar days that have elapsed since the counter was
reset to help the user track Fan runtime. Press FAN to reset.
Set Service Filter Runtime Hours (Setup Step 17) - This timer allows the user
to specify the number of hours the fan will run before the “Replace Filter”
alert will be displayed. Press COOLER continuously until
0
is displayed to
disable this alert.
Set Service Filter Calendar Days (Setup Step 18) - This timer allows the user
to specify the number of calendar days that will elapse before the “Replace
Filter” alert will be displayed. Press COOLER continuously until
0
is displayed
to disable this feature.
Setup Step
30
WARMER
COOLER
MODE
SETUP
FAN ON
AUTO