background image

Page 1

(Rev. 02/08)

L111

UL

C

US

R

Read and Save These Instructions

All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS

ISLAND RANGE HOOD

Read All Instructions Thoroughly Before Beginning Installation

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,

OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by qualified

person(s) in accordance with all applicable codes and standards,
including fire-rated construction. Switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally during installation.

B. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

C. Ducted fans must always be vented to the outdoors.

D. Sufficient air is needed for proper combustion and exhausting of

gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and
the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and local code authorities.

WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL

DUCTWORK

Summary of Contents for ISLAND RANGE HOOD

Page 1: ...ervice disconnecting means to prevent power from being switched on accidentally during installation B When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden uti...

Page 2: ...ssible Avoid sharp angled turns Instead use smooth gradual turns such as adjustable elbows or 45 degree angled turns For duct runs over 20 feet increase the duct diameter by one inch for every ten fee...

Page 3: ...ner mounting flanges on the top of the duct cover 4 Install the duct s from the outside of the home down to the location of the exhaust outlet s on the top of the transition plus 1 This will allow the...

Page 4: ...sland Connection Diagram 60 66 Widths 18 Tall Island Connection Diagram 36 54 Widths 600 CFM T200 Dual Blower Top View 1200 CFM T2 200 Dual Blowers Top View 30 Tall Island Connection Diagram 60 66 Wid...

Page 5: ...through the wire clamp s Tighten the clamp s SKIP STEP 10 PROCEED DIRECTLY TO STEP 11 10 FOR HOODS WITH REMOVABLE BLOWER MOUNTING ASSEMBLIES ONLY IF HOOD DOES NOT HAVE A REMOVABLE BLOWER MOUNTING ASS...

Page 6: ...E A REMOVABLE BLOWER MOUNTING ASSEMBLY PROCEED DIRECTLY TO STEP 14 Attach the transition s to each deck blower assembly and seal with duct tape The transition must fit inside the exhaust collar on the...

Page 7: ...10 RD MODEL DIM WALL LOUVER 11 2 FLANGE 13 13 VP555 12 RD MODEL DIM ADJUSTABLE ELBOW 6 7 8 ROUND VP513 6 VP514 7 VP515 8 MODEL DIM 11 16 11 10 3 1 4 6 VP550 6 3 1 4 x10 MODEL DIM VP561 8 6 x 8 1 2 MOD...