Page 5
(Rev. 02/08)
L111
Model
Volts
Amps
RPM
CFM
SP@0.0”
Equivalent CFM
CFM
SP@0.1”
CFM
SP@0.2”
CFM
SP@0.3”
Minimum Round
Duct Size
Square
Inches
#
T200 Island Dual
115
3.4
1550
600
900
572
540
480
8” (or equivalent)
50
Note: Add 2.5 amps for each warming light and 0.5 amp for each halogen light.
Because the Magic Lung uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently
than other than other filtration systems. When comparing the Magic Lung with other blower units made by other manufacturers, use the “Equivalent CFM”.
*
TM
TM
TM
*
#
Installation Details Continued
Warning: Make sure power is off and locked at the service disconnecting
means on the service panel during installation.
Warning: Do not operate hood without proper ground connection.
9) FOR HOODS WITH NON-REMOVABLE BLOWER MOUNTING ASSEMBLIES ONLY. IF HOOD HAS A REMOVABLE BLOWER
MOUNTING ASSEMBLY, PROCEED DIRECTLY TO STEP 10. Remove the three screws retaining each blower motor.
Unplug and remove the motors, taking care not to damage the blower wheels. It is not necessary to remove the blower
wheels from the motors.
Attach the transition to each dual blower assembly and seal with duct tape. The transition must fit inside the exhaust
collar on the blower assembly.
Install an appropriate 1/2” UL listed electrical wire clamp through each motor box electrical opening on top of the
hood. Install electrical wiring from the service panel to the hood location for each motor box. Consult the connection
diagrams (previous page) for further details on electrical placement. Feed the electrical wire(s) through the wire
clamp(s). Tighten the clamp(s). SKIP STEP 10. PROCEED DIRECTLY TO STEP 11.
10) FOR HOODS WITH REMOVABLE BLOWER MOUNTING ASSEMBLIES ONLY. IF HOOD DOES NOT HAVE A REMOVABLE
BLOWER MOUNTING ASSEMBLY, PROCEED DIRECTLY TO STEP 11. Raise the hood to its final position and attach it
to the load-bearing framework in the ceiling using appropriate hardware or to the duct cover(s) using the screws
previously removed in Step 3. From inside the hood, using UL listed wire nuts, attach the “neutral” wire(s) to the white
lead(s), the “hot” wire(s) to the black lead(s), and the ground wire(s) to the green lead(s). SKIP STEP 11 AND 12.
PROCEED DIRECTLY TO STEP 13.
7) FOR HOODS WITH REMOVABLE BLOWER MOUNTING ASSEMBLIES ONLY. IF HOOD DOES NOT HAVE A REMOVABLE
BLOWER MOUNTING ASSEMBLY, PROCEED DIRECTLY TO STEP 9. Remove each blower deckassembly by removing
the 12 screws around the blower mounting plate. Unplug the electrical connector and set the blower assembly aside,
taking care not to damage blower wheels.
8) Install an appropriate 1/2” UL listed electrical wire clamp through the electrical strap(s) on the top of the hood deck.
Install electrical wiring from the service panel to the hood location for each blower assembly. Consult the connection
diagrams (previous page) for further details on electrical placement. Support the hood under the location where it will
hang and feed the electrical wire(s) through the wire clamp(s). Tighten the clamp(s). SKIP STEP 9. PROCEED DIRECTLY
TO STEP 10.
11) FOR HOODS WITH NON-REMOVABLE BLOWER MOUNTING ASSEMBLIES ONLY. IF HOOD HAS A REMOVABLE BLOWER
MOUNTING ASSEMBLY, PROCEED DIRECTLY TO STEP 12. While taking care to properly align the duct connection
between the transition(s) and the duct(s) in the ceiling, raise the hood to its final position and attach it to the load-
bearing framework in the ceiling using appropriate hardware or to the duct cover(s) using the screws previously
removed in Step 3.