2
Installation and Wiring Instructions for the Multihome Extract Fans.
IMPORTANT:
READ THESE INSTRUCTIONS BEFORE COMMENCING THE INSTALLATION
Do not install this product in areas where the following may be present or occur:
Excessive oil or a grease laden atmosphere.
Corrosive or flammable gases, liquids or
vapours.
Subject to direct water spray from hoses.
Ambient temperatures higher than 40°C
and lower than -20°C.
Possible obstructions that may hinder
access to or removal of the unit.
All wiring must be in accordance with the current IEE wiring regulations BS7671, or appropriate standards
of your country. Installation should be inspected and tested by a suitably qualified person after completion.
Ensure the mains supply (voltage, frequency and phase) complies with the rating label.
The unit should be provided with a local double pole fused spur fitted with a 3A fuse having a contact
separation of at least 3mm.
This appliance incorporates an earth connection for functional purposes only
Precautions must be taken to avoid the back-flow of gases into the building from the open flue of gas or
other fuel-burning appliances.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
Young children should be supervised to ensure that they do not play with the appliance.
Cleaning and user maintenance shall not be done by children
The installer is responsible for the installation and electrical connection of the unit on site. It is the
responsibility of the installer to ensure that the equipment is safely and securely installed and left only
when mechanically and electrically safe.
All regulations and requirements must be strictly followed to prevent hazards to life and property, both
during and after installation, and during any subsequent servicing and maintenance.
Certain applications may require the installation of sound attenuation to achieve the sound levels required.
The unit must not be connected directly to a tumble drier.
The exhaust grille should be located at least 600mm away from any flue outlet.
This product and associated duct installation should be carried out in accordance with the Domestic
Ventilation Compliance Guide.
Models that support Radio and Bluetooth communication the below applies
Bluetooth variants contain FCC ID: S9NSPBTLERF
Bluetooth LE: -
12dBm EIRP (63μW), nominal 2450MHz.
Bluetooth v4.1 compliant
Bluetooth and radio variants obtained RED certificate: No. 0051-RED-0011 REV. 0
Zirconia Wireless: -14dBm EIRP nominal 868MHz.
The manufacturer hereby assure that this type of Bluetooth radio and 868MHz radio
equipment complies with RED Directive 2014/53 / EU
The full text of the EU Declaration of Conformity can be found at the following URL:
https://www.vent-axia.com/range/centralised-mechanical-extract-ventilation-mev
Summary of Contents for 1003000074
Page 6: ...6 Figure 5 Figure 6...
Page 26: ...26 Figure 7...
Page 36: ...36 Batterie Commutateur vitesse 4 voies 230 V...