PRODUCT FICHE 

For Residential Ventilation Units (Complying Commission Delegated Regulation (EU) No 

1254/2014) - Continued 

Timer Models: 

Name:

Vent

Axia

 

Vent

Axia

 

Vent

Axia

 

Vent

Axia

 

Vent

Axia

 

Model

 

ID

 

(Stock

 

Ref.)

 

:

ACM

 

100T

 ‐ 

17104020F

  

ACM

 

125T

 ‐ 

17105020C

ACM150T

 ‐ 

17106020D

ACM160T

 ‐ 

17107020B

ACM200T

 ‐ 

17108020B

Declared

 

as:

 

RVU

 

or

 

NRVU/UVU

 

or

 

BVU

NRVU/UVU

NRVU/UVU

NRVU/UVU

NRVU/UVU

NRVU/UVU

Speed

 

Drive

Multi

 

Speed

Multi

 

Speed

Multi

 

Speed

Multi

 

Speed

Multi

 

Speed

Type

 

HRS

 

(Recuperative,

 

Regenerative,

 

None)

None

None

None

None

None

Thermal

 

Eff:

 

[

 

(%),

 

NA(if

 

none)]

N/A

N/A

N/A

N/A

N/A

Nominal

 

Flow

 

Rate

 

(m3/s)

0.06

0.07

0.11

0.11

0.18

Effective

 

Elec.

 

Power

 

Input

 

(kW):

 

(@Nom.Flow

 

Rate&Ext.

 

Pressure)

0.02

0.03

0.05

0.05

0.10

SFPint

 

[W/(m3/s)]

N/A

N/A

N/A

N/A

N/A

Face

 

Velocity

 

(m/s)

 

@

 

Design

 

Flow

 

Rate

 

N/A

N/A

N/A

N/A

N/A

Nominal

 

External

 

Pressure:

 

(

Δ

p

s,

 

ext

)

 

in

 

Pa

71

74

92

92

167

Internal

 

Pressure

 

Drop

 

of

 

Ventilation

 

Components

 

(

Δ

p

s,int

)

 

in

 

Pa;

N/A

N/A

N/A

N/A

N/A

Additonal

 

Internal

 

Press.

 

Drop

 

of

 

Non

Ventilation

 

Comp.:

 

Δ

p

s,add

  

(Pa)

N/A

N/A

N/A

N/A

N/A

Static

 

Eff.

 

of

 

fans

 

used

 

in

 

accordance

 

with

 

Regulation

 

(EU)

 

No

 

327/2011;

TBC

 

TBC

 

TBC

 

TBC

 

TBC

 

Declared:

 ‐

Max

 

Internal

 

&

 

External

 

Leakage

 

Rates(%)

 

for

 

BVUs

 

or

 

carry

 

over

 

(for

 

regenerative

 

heat

 

exchangers

 

only),

                                 

&Ext.

 

Leakage

 

Rates

 

(%)

 

for

 

Ducted

 

UVUs;

N/A

N/A

N/A

N/A

N/A

Energy

 

Performance,

 

preferably

 

energy

 

classification,

 

of

 

the

 

Filters

 

(declared

 

information

 

about

 

the

 

calculated

 

AEC)

N/A

N/A

N/A

N/A

N/A

Filter

 

Warning

 

(RVU)

No

No

No

No

No

For

 

UVUs

 

(Instructions

 

Install

 

Grilles

 

Façade)

In

 

F&W

In

 

F&W

In

 

F&W

In

 

F&W

In

 

F&W

Internet

 

Address

 

(for

 

Disassembly

 

Instructions)

www.vent

axia.com

www.vent

axia.com

www.vent

axia.com

www.vent

axia.com

www.vent

axia.com

Summary of Contents for ACM100 B

Page 1: ...IONS ACM In Line MIXED FLOW FANS Stock Ref N ACM100 B 17104010D ACM100 T 17104020F ACM125 B 17105010D ACM125 T 17105020C ACM150 B 17106010C ACM150 T 17106020D ACM160 B 17107010B ACM160 T 17107020B ACM200 B 17108010C ACM200 T 17108020B Installation and Wiring Instructions 220 240V 50Hz IP44 ...

Page 2: ...y and MUST be installed by a suitably qualified person B The Fan should be provided with a local double pole isolator switch having a contact separation of at least 3mm C Ensure that the mains supply Voltage Frequency and Phase complies with the rating label D The Fan should only be used in conjunction with the appropriate Vent Axia products E It is recommended that the connection to the fan conne...

Page 3: ...d it should be fully extended to obtain the best results Position the fan at the highest point on the system with both ducting runs sloping downwards from this point The airflow direction is indicated on the rating label with an arrow pointing in the direction of the airflow In circumstances where an excessive amount of moisture is present in the air then a condensation trap should be installed Re...

Page 4: ...e terminal box cover screws Fig 13 6 Ensure the impeller rotates and is free from obstructions Timer models cannot be used with a speed controller Timer Adjustment The fan must be wired to a remote switch e g light switch When switched ON the fan will operate at the selected speed and will continue to run for a preset time after the fan is switched OFF The timer is factory set at 15 minutes approx...

Page 5: ...OT be used with the timer version C OVER HEATING PROTECTION The fan motor is fitted with Thermal Overload Protection This is a one shot thermal fuse In the event of a fault condition the fan will be automatically switched off If this occurs isolate the fan and call your service engineer D SERVICING AND MAINTENANCE WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPP...

Page 6: ...ace Velocity m s Design Flow Rate N A N A N A N A N A Nominal External Pressure Δps ext in Pa 71 74 92 92 167 Internal Pressure Drop of Ventilation Components Δps int in Pa N A N A N A N A N A Additonal Internal Press Drop of Non Ventilation Comp Δps add Pa N A N A N A N A N A Static Eff of fans used in accordance with Regulation EU No 327 2011 TBC TBC TBC TBC TBC Declared Max Internal External Le...

Page 7: ...A N A Face Velocity m s Design Flow Rate N A N A N A N A N A Nominal External Pressure Δps ext in Pa 71 74 92 92 167 Internal Pressure Drop of Ventilation Components Δps int in Pa N A N A N A N A N A Additonal Internal Press Drop of Non Ventilation Comp Δps add Pa N A N A N A N A N A Static Eff of fans used in accordance with Regulation EU No 327 2011 TBC TBC TBC TBC TBC Declared Max Internal Exte...

Page 8: ...fective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with the instructions given with each unit Has not been connected to an unsuitable electricity supply The correct electricity supply voltage is shown on the product rating label attached to the unit Has not been subjected to misuse neglect or d...

Reviews: