background image

 8

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Head Office: Fleming Way, Crawley, West Sussex, RH10 9YX. Tel: 01293 526062 Fax: 01293 551188 
 

UK NATIONAL CALL CENTRE

, Newton Road, Crawley, West Sussex, RH10 9JA

 

SALES ENQUIRIES: 

  

Tel: 0344 8560590  

Fax: 01293 565169

  

TECHNICAL SUPPORT: 

Tel: 0344 8560594  

Fax: 01293 532814 

For details of the warranty and returns procedure please refer to www.vent-axia.com or write to Vent-Axia Ltd, Fleming Way, Crawley, RH10 9YX

 

 
409945B 

 

 

 

 

 

 

 

 

 

                                    0716 

 

The

 

 

Guarantee 

 

Applicable only to products installed and used in the United Kingdom.  For details of guarantee outside the United Kingdom contact your local 

supplier. 

 

Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship.  In the event of any part being found 

to be defective, the product will be repaired, or at the Company’s option replaced, without charge, provided that the product:- 

 

 

Has been installed and used in accordance with the instructions given with each unit. 

 

Has not been connected to an unsuitable electricity supply. (The correct electricity supply voltage is shown on the product rating label 
attached to the unit). 

 

Has not been subjected to misuse, neglect or damage. 

 

Has not been modified or repaired by any person not authorised by the company. 

 

IF CLAIMING UNDER TERMS OF GUARANTEE 

Please return the complete product, carriage paid to your original supplier or nearest Vent-Axia Centre, by post or personal visit.  Please ensure 

that it is adequately packed and accompanied by a letter clearly marked “Guarantee Claim” stating the nature of the fault and providing evidence of 

date and source of purchase. 

 

The guarantee is offered to you as an extra benefit, and does not effect your legal rights 

Summary of Contents for ACM100 B

Page 1: ...IONS ACM In Line MIXED FLOW FANS Stock Ref N ACM100 B 17104010D ACM100 T 17104020F ACM125 B 17105010D ACM125 T 17105020C ACM150 B 17106010C ACM150 T 17106020D ACM160 B 17107010B ACM160 T 17107020B ACM200 B 17108010C ACM200 T 17108020B Installation and Wiring Instructions 220 240V 50Hz IP44 ...

Page 2: ...y and MUST be installed by a suitably qualified person B The Fan should be provided with a local double pole isolator switch having a contact separation of at least 3mm C Ensure that the mains supply Voltage Frequency and Phase complies with the rating label D The Fan should only be used in conjunction with the appropriate Vent Axia products E It is recommended that the connection to the fan conne...

Page 3: ...d it should be fully extended to obtain the best results Position the fan at the highest point on the system with both ducting runs sloping downwards from this point The airflow direction is indicated on the rating label with an arrow pointing in the direction of the airflow In circumstances where an excessive amount of moisture is present in the air then a condensation trap should be installed Re...

Page 4: ...e terminal box cover screws Fig 13 6 Ensure the impeller rotates and is free from obstructions Timer models cannot be used with a speed controller Timer Adjustment The fan must be wired to a remote switch e g light switch When switched ON the fan will operate at the selected speed and will continue to run for a preset time after the fan is switched OFF The timer is factory set at 15 minutes approx...

Page 5: ...OT be used with the timer version C OVER HEATING PROTECTION The fan motor is fitted with Thermal Overload Protection This is a one shot thermal fuse In the event of a fault condition the fan will be automatically switched off If this occurs isolate the fan and call your service engineer D SERVICING AND MAINTENANCE WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPP...

Page 6: ...ace Velocity m s Design Flow Rate N A N A N A N A N A Nominal External Pressure Δps ext in Pa 71 74 92 92 167 Internal Pressure Drop of Ventilation Components Δps int in Pa N A N A N A N A N A Additonal Internal Press Drop of Non Ventilation Comp Δps add Pa N A N A N A N A N A Static Eff of fans used in accordance with Regulation EU No 327 2011 TBC TBC TBC TBC TBC Declared Max Internal External Le...

Page 7: ...A N A Face Velocity m s Design Flow Rate N A N A N A N A N A Nominal External Pressure Δps ext in Pa 71 74 92 92 167 Internal Pressure Drop of Ventilation Components Δps int in Pa N A N A N A N A N A Additonal Internal Press Drop of Non Ventilation Comp Δps add Pa N A N A N A N A N A Static Eff of fans used in accordance with Regulation EU No 327 2011 TBC TBC TBC TBC TBC Declared Max Internal Exte...

Page 8: ...fective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with the instructions given with each unit Has not been connected to an unsuitable electricity supply The correct electricity supply voltage is shown on the product rating label attached to the unit Has not been subjected to misuse neglect or d...

Reviews: