11
IF DIFFERENT RUNNING TIMES ARE REQUIRED, REFER TO THE USER HAND BOOK.
G:7
Adjusting the Boost Airflow Rates
Press the
“ V ” “
Λ
” and `set’ Keys for more than
5 seconds until the display changes
to the screen opposite.
Press the “
Λ
” until the display
changes to the screen opposite.
The present rate number for each is shown.
Press `SET’ to adjust intake rate,
`SET’ again for Exhaust rate and SET again to
store the new values.
Air Minder Plus 290
rate numbers and corresponding
Airflow rates, Nominal setting
shown bold
Air Minder Plus 375
rate numbers and corresponding
Airflow rates, Nominal setting
shown bold
v
v
SET
R u n n i n g
T i m e
0 0 0 2 0
v
v
SET
I n t a k
E x h a
1 2
u s t
1 2
B
B
e
House size 1
Low
1 60
Medium
5 120
Boost
3 80 4 90 5 120 6 140 7 160 8 180
9 200
House size 2
Low
2 70
Medium
6 140
Boost
4 90 5 120 6 140 7 160 8 180 9 200
10 230
House size 3
Low
3 80
Medium
7 160
Boost
5 120 6 140 7 160 8 180 9 200 10 230
11 270
House size 4
Low
4 90
Medium
8 180
Boost
6 140 7 160 8 180 9 200 10 230 11 270
12 290
House size 1
Low
1 90
Medium
5 180
Boost
3 120 4 135 5 180 6 210 7 240 8 270
9 290
House size 2
Low
2 100
Medium
6 210
Boost
4 135 5 180 6 210 7 240 8 270 9 290
10 330
House size 3
Low
3 120
Medium
7 240
Boost
5 180 6 210 7 240 8 270 9 290 10 330
11 360
House size 4
Low
4 135
Medium
8 270
Boost
6 210 7 240 8 270 9 290 10 330 11 360
12 380