IF DIFFERENT RUNNING TIMES ARE REQUIRED, REFER TO THE USER HAND BOOK. 

 

G:7 

Adjusting the Boost Airflow Rates 

 

Press the

 

“ V ” “

Λ

 ” and `set’ Keys for more than  

5 seconds until the display changes  
to the screen opposite. 
 
 
Press the “

Λ

 ” until the display  

changes to the screen opposite. 
 
 
 
The present rate number for each is shown.  
Press `SET’ to adjust intake rate,  
`SET’ again for Exhaust rate and SET again to  
store the new values. 
 
 

Air Minder Plus 290

  

rate numbers and corresponding 
Airflow rates, Nominal setting 
shown bold 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Air Minder Plus 375

  

rate numbers and corresponding 
Airflow rates, Nominal setting 
shown bold 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

v

v

SET

R u n n i n g

T i m e

0 0 0 2 0

v

v

SET

I n t a k

E x h a

1 2

u s t

1 2

B

B

e

House size 1
Low

   1    60

Medium

   5    120 

 

 

Boost

   3    80    4     90   5    120  6    140  7    160   8    180  

9    200

House size 2
Low

   2    70

Medium

   6   140 

 

 

Boost

   4   90     5    120  6    140  7    160   8   180   9   200   

10  230

House size 3
Low

   3    80

Medium

  7   160 

 

  

Boost

   5   120   6    140  7    160  8    180   9   200   10  230  

11  270

House size 4
Low

   4     90

Medium

  8    180 

 

  

Boost

   6    140 7    160   8   180   9    200  10   230 11   270 

12   290

House size 1
Low

   1    90

Medium

  5   180 

 

  

Boost

   3   120   4    135  5    180  6    210   7   240   8    270  

9   290 

 

House size 2
Low

   2   100

Medium

  6   210 

 

Boost

   4   135   5   180   6   210   7    240   8   270   9   290  

10   330

 

House size 3
Low

   3   120

Medium

  7   240 

 

 

Boost

   5   180   6    210  7    240  8    270   9   290  10   330 

11   360

House size 4
Low

   4   135

Medium

8   270

 

 

Boost

   6   210   7   240   8    270  9   290   10  330   11  360  

12  380

Summary of Contents for Air Minder Plus

Page 1: ...ABC WHOLE HOUSE HEAT RECOVERY UNIT Installation Connection and set up Instructions READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS...

Page 2: ...applications may require the installation of sound attenuation to achieve the sound levels required The unit must not be connected directly to a Cooker Hood or Tumble Dryer The Condensate Waste pipe...

Page 3: ...ONTROLLER Carton 2 8 TWO FAN BLOWER UNITS 9 TWO INLETS CARTON 2 ITEM 8 2 off ITEM 9 2 off A PREPARATION 1 Remove the contents from Carton 1 2 Remove the Air Filters from the main body 3 Release the si...

Page 4: ...on the other side of the Base Housing Inlet Item 9 Inlet Item 9 Fan blower unit Item 8 Fan blower unit Item 8 Electrical control box Ensure the Fan Units Item 8 are on either side of the Electrical Co...

Page 5: ...diagram below for loft or ceiling mounting Condensate connection Condensate connection Roofing joist Fit assembled 5 angled brackets Ceiling joist Fit assembled 5 angled brackets Loft mounting Ceiling...

Page 6: ...ns in the Tubing Note Ensure that units are installed with a 5 fall towards the condensate drain point 2 Connect the tubing Item 2 to Drain Elbow and secure into position with a Clip Band Align the el...

Page 7: ...tersink at the top of the slots provides permanent fixing Fixing Slots CONTROLLER 1 The 4 core SELV cable is wired to the controller terminals in the following order 2 Replace the Controller s front c...

Page 8: ...Low 90 m3 h Med 120 m3 h Med 140 m3 h Med 160 m3 h Med 180 m3 h High 200 m3 h High 230 m3 h High 270 m3 h High 290 m3 h AM PLUS 375 House Volume 400m3 466m3 555m3 600m3 Low 90 m3 h Low 100 m3 h Low 12...

Page 9: ...our will remain on and the Minutes will start to flash G 4 Setting the Minutes Press the or V Key to set the Minutes Press the Set Key the Minutes will remain on and the display will scroll to the nex...

Page 10: ...scribed in the Fitting and Wiring information Air Minder Plus 290 rate numbers and corresponding Airflow rates Nominal setting shown bold Air Minder Plus 375 rate numbers and corresponding Airflow rat...

Page 11: ...ng shown bold v v SET R u n n i n g T i m e 0 0 0 2 0 v v SET I n t a k E x h a 1 2 u s t 1 2 B B e House size 1 Low 1 60 Medium 5 120 Boost 3 80 4 90 5 120 6 140 7 160 8 180 9 200 House size 2 Low 2...

Page 12: ...s not permitted a link must be fitted between the JP 200 terminals on the HRU Control Panel When this link is in position and the external air temperature drops below 1 C the summer bypass will open a...

Page 13: ...against faulty material or workmanship In the event of any part being found to be defective the product will be repaired or at the Company s discretion the product will be replaced without charge pro...

Reviews: