background image

 

       

10

 

 

 

PRODUCT

 

FICHE

 

For

 

Residential

 

Ventilation

 

Units

 

(Complying

 

Commission

 

Delegated

 

Regulation

 

(EU)

           

No

 

1254/2014)

 

 

Name:

  

Vent

Axia

  

Model

 

ID

 

(Stock

 

Ref.)

 

:

 

HR

 

200

 

V

 ‐ 

14120010

 

SEC

 

Class

 

C

 

SEC

 

Value

 

('Average')

 

25.44

 

SEC

 

Value

 

('Warm')

 

4.28

 

SEC

 

Value

 

('Cold')

 

63.16

 

Label

 

Required?

 

(Yes/No=Out

 

of

 

scope)

 

Yes

 

Declared

 

as:

 

RVU

 

or

 

NRVU/UVU

 

or

 

BVU

 

RVU/BVU

  

Speed

 

Drive

 

Multi

Speed

 

Type

 

HRS

 

(Recuperative,

 

Regenerative,

 

None)

 

Recuperative

  

Thermal

 

Eff:

 

[

 

(%),

 

NA(if

 

none)]

 

70

 

Max.

 

Flow

 

Rate

 

(m3/h)

 

198.0

 

Max.

 

Power

 

Input

 

(W):

 

(@Max.Flow

 

Rate)

 

110

 

LWA:

 

Sound

 

Power

 

Level

 

(dB)

 

66.13

 

Ref.

 

Flow

 

Rate

 

(m3/s)

 

0.039

 

Ref.

 

Pressure

 

Diff.

 

(Pa)

 

80

 

SPI

 

[W/(m3/h)]

 

0.43

 

Control

 

Factor

 

&

 

Control

 

Typology:

 

(CTRL/

 

Typology)

 

  

Control

 

Factor;

 

CTRL

 

1.00

 

Control

 

Typology

 

Manual

 

Control

 

Declared:

 ‐

Max

 

Internal

 

&

 

External

 

Leakage

 

Rates(%)

 

for

 

BVUs

 

or

 

carry

 

over

 

(for

 

regenerative

 

heat

 

exchangers

 

only),

                                                                                                                         ‐

&Ext.

 

Leakage

 

Rates

 

(%)

 

for

 

Ducted

 

UVUs;

 

<5%

 

Internal,

 

<5%

 

External

 

Mixing

 

Rate

 

of

 

Non

Ducted

 

BVUs

 

not

 

intended

 

to

 

be

 

equipped

 

with

 

one

 

duct

 

connection

 

on

 

either

 

supply

 

or

 

extract

 

air

 

side;

 

N/A

 

Position

 

and

 

description

 

of

 

visual

 

filter

 

warning

 

for

 

RVUs

 

intended

 

for

 

use

 

with

 

filters,

 

including

 

text

 

pointing

 

out

 

the

 

importance

 

of

 

regular

 

filter

 

changes

 

for

 

performance

 

and

 

energy

 

efficiency

 

of

 

the

 

unit

 

N/A

 

For

 

UVUs

 

(Instructions

 

Install

 

Regulated

 

Supply/Extract

 

Grilles

 

Façade)

 

N/A

 

Internet

 

Address

 

(for

 

Disassembly

 

Instructions)

 

www.vent

axia.com

 

Sensitivity

 

p.

 

Var20/

20

 

Pa:

 

(for

 

Non

Ducted

 

VUs)

 

N/A

 

Air

 

Tightness

ID/OD

(m3/h)

 

(for

 

Non

Ducted

 

VUs)

 

N/A

 

Annual

 

Electricity

 

Consumption:

 

AEC

 

(kWh/a)

 

5.87

 

Annual

 

Heating

 

Saved:

 

AHS

 

(kWh/a)

 

  

AHS:

 

Average

 

39.45

 

AHS:

 

Warm

 

17.84

 

AHS:

 

Cold

 

77.17

 

Summary of Contents for HR200V

Page 1: ...HR200V Ducted Heat Recovery Ventilator Installation and Maintenance Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Stock Ref No HR200V 14120010...

Page 2: ...re that they do not play with the appliance INSTALLATION GUIDANCE 1 The installer is responsible for the installation and electrical connection of the sentinel system on site It is the responsibility...

Page 3: ...3 Warnings Safety Information Contents Section Page 1 0 Introduction 4 2 0 Site Requirements 5 3 0 Installation 6 4 0 Electrical 8 5 0 Maintenance 9...

Page 4: ...lation ducting 3 The maximum power consumption for the unit is 108w 4 The twin impeller and heat exchanger arrangement simultaneously supplies and extracts air while transferring heat from the stale e...

Page 5: ...he unit must be sited such that the ambient temperature will not exceed 40 C 9 Do not site the appliance in the vicinity of excessive levels of airborne oil or grease 10 If the unit is installed in a...

Page 6: ...ect an approved electrical control arrangement for the HR200 unit above 2 After considering the site requirements Section 2 0 select a suitable site for the unit and controllers and work out the cable...

Page 7: ...he installation site and fix it in position using four suitable screws and the remaining four supplied washers The washers should be located between the screw heads and the mounting grommets CAUTION E...

Page 8: ...es as shown in Fig 5 to a Switched fused spur or a control unit If a controller is used follow the fitting and wiring instructions supplied with the controller ensuring that the black and brown wires...

Page 9: ...of contamination experienced and according to the following procedure 3 Isolate the mains power supply 4 Remove the ducting to internal grilles Undo the two grille securing screws and remove the spig...

Page 10: ...Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs 5 Internal 5 External Mixing Rate of Non Ducted BVU...

Page 11: ......

Page 12: ...rating label attached to the unit Has not been subjected to misuse neglect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE...