2.0   Site Requirement

 

 

 

2.1 

Information

 

 

1. The unit is designed for mounting in a ceiling 
void and connected to inlet and outlet grilles with 
150mm diameter ducting. Dimensions of the unit 
are shown In Fig.1.

 

 

2. Warning: This appliance is class I and it 
must therefore be earthed.

 

 

3. The unit must be sited and connected by a 
suitably competent person and be in accordance 
with current UK Building Regulations and I.E.E. 
Wiring Regulations (BS 7671).

 

 

4. The unit is intended for permanent connection 
to the mains electrical supply.

 

 

5. The unit is intended for fixed wiring installation.

 

 

6. Wiring to the unit in the UK must be via a 
switched fused spur. The switched fused spur 
must have a 3mm minimum contact gap in all 
poles.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7. Ensure that the mains electrical supply is 
compatible with the rating label attached to the 
product.

 

 

8. The unit must be sited such that the ambient 
temperature will not exceed 40° C.

 

 

9. Do not site the appliance in the vicinity of 
excessive levels of airborne oil or grease.

 

 

10. If the unit is installed in a room containing a 
fuel burning appliance, the installer must ensure 
that air replacement is adequate for both 
appliances.

 

 

11. The unit must be installed away from any source of 
water and out of reach of any person using a fixed bath or 
shower.

 

 

12. In situations where moisture can be present 
in the air, the unit should be connected to a 
drainage system.

 

 

13. The external grilles of the unit must be sited 
at least 600mm away from any flue of gas or 
solid fuel appliances. This is to avoid back flow of 
gases entering the room.

 

 

14. All safety regulations and requirements must 
be strictly followed to prevent hazards to life and 
property both during and after installation and 
during subsequent maintenance or servicing.

 

 

15. Ensure the mains electrical supply is switched 
off before commencing installation or 
maintenance.

 

Fig. 2 

Summary of Contents for HR200V

Page 1: ...HR200V Ducted Heat Recovery Ventilator Installation and Maintenance Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Stock Ref No HR200V 14120010...

Page 2: ...re that they do not play with the appliance INSTALLATION GUIDANCE 1 The installer is responsible for the installation and electrical connection of the sentinel system on site It is the responsibility...

Page 3: ...3 Warnings Safety Information Contents Section Page 1 0 Introduction 4 2 0 Site Requirements 5 3 0 Installation 6 4 0 Electrical 8 5 0 Maintenance 9...

Page 4: ...lation ducting 3 The maximum power consumption for the unit is 108w 4 The twin impeller and heat exchanger arrangement simultaneously supplies and extracts air while transferring heat from the stale e...

Page 5: ...he unit must be sited such that the ambient temperature will not exceed 40 C 9 Do not site the appliance in the vicinity of excessive levels of airborne oil or grease 10 If the unit is installed in a...

Page 6: ...ect an approved electrical control arrangement for the HR200 unit above 2 After considering the site requirements Section 2 0 select a suitable site for the unit and controllers and work out the cable...

Page 7: ...he installation site and fix it in position using four suitable screws and the remaining four supplied washers The washers should be located between the screw heads and the mounting grommets CAUTION E...

Page 8: ...es as shown in Fig 5 to a Switched fused spur or a control unit If a controller is used follow the fitting and wiring instructions supplied with the controller ensuring that the black and brown wires...

Page 9: ...of contamination experienced and according to the following procedure 3 Isolate the mains power supply 4 Remove the ducting to internal grilles Undo the two grille securing screws and remove the spig...

Page 10: ...Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs 5 Internal 5 External Mixing Rate of Non Ducted BVU...

Page 11: ......

Page 12: ...rating label attached to the unit Has not been subjected to misuse neglect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE...

Reviews: