3.0 Installation
Blind Grommet
280mm
380mm
3.3
Installing the Appliance
From Inside
1. Slide the unit into the mounting hole and
ensure that the minimum overhang requirements
are achieved inside and out (Fig. 4).
2. The HR300 requires an overhang internal and
external (Fig. 5):
Internal 50mm
External 55mm
Fig. 4
55mm
Internal
External
3. Ensure that the unit is square and true with the
outside wall face. If firmer fixings are required,
secure the unit in place with the two fixing screws
provided.
NOTE:
Ensure the fixings DO NOT inhibit
removal or replacement of the heat exchanger.
4. Make good around the case.
5. Fit the bezel on the inside to cover the making
good by pressing the bezel over the case (Fig. 6).
3° Min
CAUTION:
Ensure the case does not distort
during fixing and making good.
For Drainage
50mm
Fig.5
From Outside
1. Slide the panel flange (flange first) on to the
unit and press the flange firm against the outer
wall (Fig. 6).
2. Secure the panel flange to the wall using the
fixing screws provided. If necessary the panel
flange can be secured to the case by self-tapping
screw 25mm long maximum.
Bezel
Fig. 6
Panel Flange