background image

 

 

 

Integra Plus ECA MVHR Installation & Commissioning 

17

 

 

PRODUCT FICHE 

For Residential Ventilation Units (Complying Commission Delegated Regulation (EU)                 No 1254/2014 

 

 

Name:  

Vent-Axia  

Vent-Axia 

Model ID (Stock Ref.) : 

Integra Plus ECA - 437666ECA 

Integra Plus ECA – 437666ECA 

SEC Class 

SEC Value ('Average') 

-32.34 

-38.85 

SEC Value ('Warm') 

-11.18 

-15.86 

SEC Value ('Cold') 

-70.06 

-79.77 

Label Required? (Yes/No=Out of scope) 

Yes 

Yes 

Declared as: RVU or NRVU/UVU or BVU 

RVU/BVU 

RVU/BVU 

Speed Drive 

Multi-Speed 

Multi-Speed 

Type HRS (Recuperative, Regenerative, None) 

Recuperative  

Recuperative 

Thermal Eff: [ (%), NA(if none)] 

70 

70 

Max. Flow Rate (m3/h) 

478.80 

478.80 

Max. Power Input (W): (@Max.Flow Rate) 

167.00 

167.00 

LWA: Sound Power Level (dB) 

48.83 

48.83 

Ref. Flow Rate (m3/s) 

0.09310 

0.09310 

Ref. Pressure Diff. (Pa) 

50.00 

380.00 

SPI [W/(m3/h)] 

0.21 

0.21 

Control Factor & Control Typology: (CTRL/ Typology) 

  

 

Control Factor; CTRL 

1.00 

0.65 

Control Typology 

Manual Control 

Local Demand Control 

Declared: -Max Internal & External Leakage Rates(%) for BVUs or carry over (for 
regenerative heat exchangers only),                                                                                                                         
-&Ext. Leakage Rates (%) for Ducted UVUs; 

<5% Internal, <5% External 

<5% Internal, <5% External 

Mixing Rate of Non-Ducted BVUs not intended to be equipped with one duct 
connection on either supply or extract air side; 

N/A 

N/A 

Position and description of visual filter warning for RVUs intended for use with 
filters, including text pointing out the importance of regular filter changes for 
performance and energy efficiency of the unit 

N/A 

N/A 

For UVUs (Instructions Install Regulated Supply/Extract Grilles Façade) 

N/A 

N/A 

Internet Address (for Disassembly Instructions) 

www.vent-axia.com 

www.vent-axia.com 

Sensitivity p. Var20/-20 Pa: (for Non-Ducted VUs) 

N./A 

N./A 

Air Tightness-ID/OD-(m3/h) (for Non-Ducted VUs) 

N./A 

N./A 

Annual Electricity Consumption: AEC (kWh/a) 

3.11 

1.85 

Annual Heating Saved: AHS (kWh/a) 

  

 

AHS: Average 

39.45 

42.79 

AHS: Warm 

17.84 

19.35 

AHS: Cold 

77.17 

83.71 

Product Fiche 

Summary of Contents for Integra Plus EC

Page 1: ...Integra Integra Plus ECA MVHR Kinetic Kinetic Plus E MVHR Installation Commissioning Installation Commissioning Stock Ref N 437666ECA Integra Plus ECA PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT...

Page 2: ......

Page 3: ...nstruction concerning use of the appliance by a person responsible for their safety 8 Young children should be supervised to ensure that they do not play with the appliance INSTALLATION GUIDANCE 1 The...

Page 4: ...p the Unit 14 Commissioning Overview 14 Modes of Operation 15 Maintenance 16 Spares 16 PRODUCT FICHE 17 UK Building Regulations Part F Declaration of Conformance Integra Plus ECA conform to the 2010 B...

Page 5: ...lings conforming to the latest requirements of the Building Regulations document F 2010 The unit is designed for continuous 24 hour exhaust ventilation of stale moist air from bathrooms toilets and ki...

Page 6: ...Product Description Integra Plus ECA MVHR Installation Commissioning 6 Exploded View of Fan Unit Integra Plus ECA Dimensions 150 22 Cover Heat recovery cell Motor assemblies Base assembly...

Page 7: ...e pipe diameter 22 mm Environmental IP Rating IPX2 Operating Temperature 10 C to 45 C Air Intake Temperature As above Operating Humidity 0 to 95 RH Storage Temperature 10 C to 45 C Storage Humidity 0...

Page 8: ...eight of the unit that you are installing Always use appropriate lifting techniques and appliances when moving heavy equipment Check Site Requirements and Safety Notices Check that the physical and en...

Page 9: ...3 5 TOWARDS THE CONDENSATE DRAIN CONDENSATION DRAIN THE UNIT SHOULD SLOPE DOWNWARDS BY 3 5 TOWARDS THE CONDENSATE DRAIN CONDENSATION DRAIN THE UNIT SHOULD SLOPE DOWNWARDS BY 3 5 TOWARDS THE CONDENSATE...

Page 10: ...Ceiling mounted Invert the unit with the Vent Axia logo facing down and attach the unit securely to the rafters For optimum performance ensure the ductwork does not turn 90 directly off the spigots T...

Page 11: ...20 240 V AC 50 Hz input N Mains Neutral Blue 220 240 V AC 50 Hz input EARTH Mains Earth Yellow Green Earth connector LS1 Switched Live 1 Black 220 240 V AC 50 Hz input LS2 Switched Live 2 Black colour...

Page 12: ...d to the unit and routed into the control housing via a suitable gland to ensure the IP rating of the unit is not affected 3 Connect the other end of the cable to the switched fused spur 4 Use cable c...

Page 13: ...ly the boost button on the Remote Boost Switch may be used LS1 and LS2 inputs can be from a lighting circuit or other mains voltage supply alternatively an optional external control unit can be used N...

Page 14: ...rating any acoustic ducting that all joints are air tight ducting is well supported bends are avoided close to vents and that the vent valves are fully open at the start of the commissioning process C...

Page 15: ...and can only be triggered and cancelled via the Remote Boost switch A 5 second press and hold of the Boost Switch will trigger or cancel Purge Mode Purge mode will timeout after 30 minutes The LED wi...

Page 16: ...r and heat exchanger in warm water using a mild detergent such as Milton Fluid and dry thoroughly NOTE Keep water away from all electrical components and wiring within the unit Motors Inspect the moto...

Page 17: ...Factor CTRL 1 00 0 65 Control Typology Manual Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates...

Page 18: ...Notes...

Page 19: ...Integra Plus ECA MVHR Installation Commissioning 19 Notes...

Page 20: ...y part being found to be defective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with the instruct...

Reviews: